Digit #1, 2 - Unit Type [UT]

Digit #12 - Motor Type [MT]

SF - Separated Combustion Tubular Propeller

1 - Open Drip Proof (Standard)

2 - Totally Enclosed

Digit #3, 4, 5 - Capacity [CA]

100 - 100,000 BTU/HR

Digit #13 - Blower Motor Sizes [MS]*

125 - 125,000 BTU/HR

0 - None/Not Applicable

150 - 150,000 BTU/HR

*Note: Blower Motor Size [MS] not applicable for propeller type unit heaters.

175 - 175,000 BTU/HR

200 - 200,000 BTU/HR

250 - 250,000 BTU/HR

Digit #14 - Accessories [AS]

300 - 300,000 BTU/HR

350 - 350,000 BTU/HR

FACTORY INSTALLED

400 - 400,000 BTU/HR

M6 - OSHA Type Fan Guard

S3 - 409 Stainless Steel Flue Collector

P4 - Terminal Block Wiring

S5 - 304L Stainless Steel Burners

Digit #6 - Furnace Type [FT]

P6 - Summer/Winter Switch

A - Right Side Access

Digit #7 - Heat Exchanger Construction Material [FM]

1 - Standard (Aluminized) Steel

† FIELD INSTALLED (AS-____ )

2 - 409 Stainless Steel

All Field Installed Accessories are to be entered as a separate line item using catalog

number which utilizes “AS” as a prefi x. i.e: A7 becomes AS-A7.

Digit #8 - Gas Type [GT]

N - Natural Gas

A7 - Pressure Regulator 1/2-2 psi

P5 - 24V SPST Relay-Specify Purpose

P - Propane Gas (LP)

G1 - 1-Stage T87K Mercury Free Thermostat

X2 - 30 Degree Downturn Nozzle

Digit #9 - Altitude [AL]

w/Subbase Kit

X3 - 60 Degree Downturn Nozzle

G2 - 1-Stage T87K Mercury Free Thermostat

X4 - 90 Degree Downturn Nozzle

S - 0–4,999 ft.

w/TG511A Guard Kit

X5 - Vertical Louver Kit

T - 5,000–11,999 ft.

G3 - 1-Stage T834N Mercury Free

Note: Installations over 2,000 ft. require gas input deration in the field.

Thermostat/Fan Switch

X7-H5 - Horiz. Combustion Air Inlet Kit, 5 inch

Refer to unit installation instructions.

G5 - 2-Stage TH5220D Mercury Free

(Unit Capacity 100-250)

Thermostat w/Subbase

X7-H6 - Horiz. Combustion Air Inlet Kit, 6 inch

Digit #10 - Direct Spark Gas Control [GC]

G6 - Locking Thermostat Cover

(Unit Capacity 300-400)

1 - Single Stage

G8 - 1-Stage T6169C Line Voltage Stat

X7-V5 - Vert. Combustion Air Inlet Kit, 5 inch

2 - Two Stage

w/Subbase

(Unit Capacity 100-250)

3 - Electronic Modulation w/Room Sensing

G9 - 1-Stage T822K Mercury Free

X7-V6 - Vert. Combustion Air Inlet Kit, 6 inch

4 - Electronic Modulation w/Duct Sensing

Thermostat

(Unit Capacity 300-400)

5 - Electronic Modulation w/Duct Sensing & Room Override Stat

6 - Electronic Modulation w/External 4-20 mA Input

M2-2 - Vent Caps (5") (Unit Capacity 100-250)

7 - Electronic Modulation w/External 0-10 VDC Input

M2-3 - Vent Caps (6") (Unit Capacity 300-400)

Digit #11 - Supply Voltage [SV]

1 - 115/1/60 5 - 230/3/60

2 - 208/1/60 6 - 460/3/60

3 - 230/1/60 7 - 575/3/60

4 - 208/3/60 Z - Special

Note: Supply Voltages [SV] 2-7 include field mounted step down transformer.

SEPARATED COMBUSTION TUBULAR PROPELLER

UNIT NUMBER DESCRIPTION

DIGIT

T

X

X

X

1

2

3

4

5

6

7

8

9

10

11

12

13

14

+

ITEM

PREFIX

UT

CA

FT FM GT AL GC SV MT MS

AS

(Internal Use Only)