Automatic model determination, Scan interval, Setting the number of retries – Yokogawa DAQWORX User Manual
Page 23: Automatic model determination -3, Scan interval -3, Setting the number of retries -3, Index, Automatc model determnaton, Settng the number of retres

3-3
IM WX1-03E
1
2
3
Index
Deta
led Descr
pt
on of Funct
ons
Automatc Model Determnaton
If you select a WT and perform automatic model determination, the model and number of
channels are passed to the WT Setting tab on the configurator.
However, harmonic option output for WT1600 and harmonic mode for WT1600 are not
supported.
Models and Number of Channels (Model Name n Brackets)
Model
Number of channels
WT110 [253401]
WT110E [253451]
WT200 [253421]
WT210 [760401]
19
WT130 (2Elements) [253502]
WT230 (2Elements) [760502]
53
WT230 (3Elements) [253503]
WT230 (3Elements) [760503]
70
WT1010 [253610]
WT2010 [253101]
18
WT1030 (2Elements) [253620]
WT2030 (2Elements) [253102]
46
WT1030 (3Elements) [253630]
WT2030 (3Elements) [253103]
61
WT1030M [253640]
68
WT1600 (1Elements) [760101-01/-10]
76
WT1600 (1Elements) [760101-02/-11/-20]
123
WT1600 (1Elements) [760101-03/-12/-21/-30]
170
WT1600 (1Elements) [760101-04/-13/-22/-31/-40]
197
WT1600 (1Elements) [760101-05/-14/-23/-32/-41/-50]
224
WT1600 (1Elements) [760101-06/-15/-24/-33/-42/-51/-60]
251
WT1800 (1Elements) [WT1801-01/-10]
55
WT1800 (2Elements) [WT1802-02/-11/-20]
104
WT1800 (3Elements) [WT1803-03/-12/-21/-30]
104
WT1800 (4Elements) [WT1804-04/-13/-22/-31/-40]
179
WT1800 (5Elements) [WT1805-05/-14/-23/-32/-41/-50]
205
WT1800 (6Elements) [WT1806-06/-15/-24/-33/-42/-51/-60]
254
WT500[1Elements] (760201)
99
WT500[2Elements] (760202)
156
WT500[3Elements] (760203)
213
* The number of WT500 channels given above is with the /G5 and /DS options. If an option
is not installed, the number of channels is decreased by the number of channels related to
that option. The number of WT1800 channels given above is with the /G5 or /G6, /DT, /MTR
or /AUX options. If an option is not installed, the number of channels is decreased by the
number of channels related to that option.
Scan Interval
A scan interval from 0.5 to 3600 seconds is selected for each of the 16 WTs.
Note
When connecting to DAQLOGGER and acquiring data from the WTs, if GateWT’s scan interval
is longer than that of DAQLOGGER, DAQLOGGER logs the same data repeatedly until the
next GateWT scan interval. Therefore, it is recommended that GateWT’s scan interval be set
to a value smaller than DAQLOGGER’s scan interval.
Settng the Number of Retres
The Retry function can be turned ON and OFF for each of the 16 WTs.
If Retry is turned ON, a retry interval of 30 to 3600 seconds can be specified.
Communication is reattempted each time the specified number of seconds elapses.
Retries are also performed on instruments with which a communication error occurred
during the first communication.
3.2 Detaled Descrpton of Functons