50 Installation
7.2 WIRING DESIGNATIONS FOR THE 414D & 414B
Terminal
Model 414D
Model 414B
1
Calibration Link
Calibration Link
2
Signal Ground
Signal Ground
3
Not To Be Used
Not To Be Used
4
Remote Display Switch
Not To Be Used
5
Remote Batch Set Switch
Not To Be Used
6
Not To Be Used
Not To Be Used
7
Flow Alarm
Not To Be Used
8
Flow Common (-)
Flow Common (-)
9
Flow Pulse Input
Flow Pulse Input
10
Pulse Out
Not To Be Used
11
DC Power Out (8-24 VDC)
DC Power Out (8-24 VDC)
12
DC Ground
DC Ground
13
DC Power Input
DC Power Input
14
Not To Be Used
Not To Be Used
Terminal
RS232/422/485 Option
20
RS232 Signal Ground
21
RS232 Data In
22
RS232 Data Out
23
RS422/485 (-) Data Out
24
RS422/485 (+) Data Out
25
RS422/485 (-) Data In
26
RS422/485 (+) Data In
27
RS232 CTS
Terminal
Relay Output & Switches
28
Remote RUN Switch
29
Remote STOP Switch
30
End of Batch/Pump Control Signal
31
Relay 2 - Normally Open
32
Relay 2 - Normally Closed
33
Relay 2 - Common
34
Relay 1 - Normally Open
35
Relay 1 - Normally Closed
36
Relay 1 - Common