3 csa – Yokogawa ADMAG AXF User Manual
Page 13

IM 01E20D01-01E
8. EXPLOSION PROTECTED TYPE INSTRUMENT
Conduit
Magnetic Flowmeter
Sealing Fitting
HAZARDOUS LOCATIONS
18" (457 mm) Max.
F0802.EPS
Figure 8.2.1 Conduit Wiring
8.3 CSA
(1) Technical Data
*AXF002C – AXF400C
Applicable Standard:
For CSA C22.2 Series;
C22.2 No 0, C22.2 No 0.4, C22.2 No 0.5,
C22.2 No 25, C22.2 No 30, C22.2 No 94,
C22.2 No 157, C22.2 No.61010-1-12,
C22.2 No.61010-2-030-12
For CSA E79 Series;
CAN/CSA-E79-0, CAN/CSA-E79-1,
CAN/CSA-E79-7, CAN/CSA-E79-11,
CAN/CSA-E79-18
Certificate: 1481213
Process Sealing Certification:
Dual Seal certified by CSA to the requirements of
ANSI/ISA 12.27.01.
No additional sealing required.
Primary seal failure annunciation;
Deterioration of the flowrate output at nonzero
flow point.
Unstable flowrate output at zero flow point.
(Integral Flowmeter)
For CSA C22. 2 Series
Explosion proof for Class I, Division 1, Groups A,
B, C & D.
Dust-ignition proof for Class II/III, Division 1,
Groups E, F & G.
Intrinsically safe (electrodes) for Class I, Division 1,
Groups A, B, C & D.
“SEAL ALL CONDUITS WITHIN 50 cm OF THE
ENCLOSURE”
“WHEN INSTALLED IN DIV. 2, SEALS NOT
REQUIRED”
Electrode Circuit Um: 250 Vac/dc
Maximum power supply voltage: 250 Vac/130 Vdc
Excitation Circuit: 140V max
Enclosure: Type 4X
Temperature Code:
T27-1.EPS
+70
°C (+158°F)
+85
°C (+185°F)
Temperature
Code
+120
°C (+248°F)
Maximum Process
Temperature
–40
°C (–40°F)
–40
°C (–40°F)
–40
°C (–40°F)
–40
°C (–40°F)
T6
Minimum Process
Temperature
T4
T5
T3
+130
°C (+266°F)
Ambient Temp.: –40
°C to +60°C (–40°F to +140°F)
For CSA E79 Series
Flameproof for Zone 1, Ex dme [ia] IIC T6...T3
Intrinsically safe (electrodes), Ex ia IIC T6...T3
Electrode Circuit Um: 250 Vac/dc
Maximum power supply voltage: 250 Vac/130 Vdc
Excitation Circuit: 140V max
Enclosure: IP66, IP67
Temperature Code:
T0807.EPS
+70
°C (+158°F)
+85
°C (+185°F)
Temperature
Code
+120
°C (+248°F)
Maximum Process
Temperature
–40
°C (–40°F)
–40
°C (–40°F)
–40
°C (–40°F)
–40
°C (–40°F)
T6
Minimum Process
Temperature
T4
T5
T3
+130
°C (+266°F)
Ambient Temp.: –40
°C to +60°C (–40°F to +140°F)
(Remote Flowtube)
For CSA C22.2 Series
Explosion proof for Class I, Division 1, Groups A,
B, C & D.
Dust-ignition proof for Class II/III, Division 1,
Groups E, F & G.
Intrinsically safe (electrodes) for Class I, Division 1,
Groups A, B, C & D.
“SEAL ALL CONDUITS WITHIN 50 cm OF THE
ENCLOSURE”
“WHEN INSTALLED IN DIV. 2, SEALS NOT
REQUIRED”
Electrode Circuit Um: 250 Vac/dc
Excitation Circuit: 170V max
Enclosure: Type 4X
Temperature Code:
T28-1.EPS
Temperature
Code
Maximum Process
Temperature
–40
°C (–40°F)
–40
°C (–40°F)
–40
°C (–40°F)
–40
°C (–40°F)
T6
Minimum Process
Temperature
T4
T5
T3
+70
°C (+158°F)
+85
°C (+185°F)
+120
°C (+248°F)
+150
°C (+302°F)
Ambient Temp.: –40
°C to +60°C (–40°F to +140°F)
For CSA E79 Series
Flameproof for Zone 1, Ex dme [ia] IIC T6...T3
Intrinsically safe (electrodes), Ex ia IIC T6...T3
Electrode Circuit Um: 250 Vac/dc
Excitation Circuit: 170V max
Enclosure: IP66, IP67
8-5