beautypg.com

Pfister 8P5-CS1C User Manual

Page 5

background image

5

to remove Valve Cartridge and other Plastic Components

from the Valve Body before soldering. Use copper pipe

adapters (not furnished) in this type of installation.
6 TRIM FLANGE ATTACHMENT (Fig.C)

Position trim flange (1) with Rubber Gasket (2) onto the

valve body (3) and slide flush to wall finish. Secure with

Ring (4) onto valve body.
7 HANDLE ATTACHMENT (Fig.D)

Place Handle Hub (1) on Valve Stem (2) with O-Ring (3)

and secure with Set Screw (4) (do not over tighten). Install

Decorative Cap (5). To remove handle reverse steps.
8 VALVE FUNCTION (Fig.E)

By lifting the Lever Handle (1) up, the valve will be activated

allowing water to flow. The water flow will increase by

continuing to lift up the Lever Handle (1). By rotating the

Lever Handle counter-clockwise, the water temperature will

decrease to cold flow only. By rotating the Lever Handle

clockwise, the water temperature will increased to hot flow

only.
9 SHOWER ARM AND SHOWER HEAD

INSTALLATION (Fig.F)

For shower only products: Insert the end of Shower Arm (1)

through the Shower Flange (2). Apply PTFE plumber's tape

to both ends of Shower Arm (1) according to manufacturer's

instructions. Screw the long end of Shower Arm (1) into pipe

(3) elbow inside the wall. Slide Shower Flange (2) tight to

the wall. Screw the shower head (4) to the Shower Arm (1),

placing the Washer (5) in between.

1

4

2

3

C

1

2

3

4

5

D

1

OPEN

COLD

HOT

E

K

1

5

4

2

3

F

This manual is related to the following products: