8 FLUSHING & AERATOR CLEANING (Fig.C)
After installation is complete, remove Aerator Housing.
Turn valve on and allow both hot and cold water to run for
at least one minute each. While water is running, check for
leaks. To clean the Aerator, disassemble Aerator Housing
by separating the Aerator Head (1), Basket (2) and
Washer (3). Once parts have been cleaned, reassemble
by reversing steps.
D
1
3
2
4
9 CARTRIDGE REMOVAL (Fig.D)
Turn off water supplies and relieve pressure before
working on your faucet! Loosen Set Screw (1) and
remove Handle (2). Remove the Dome Cap (3) by
unscrewing counterclockwise. Carefully remove the
Cartridge (4) by pulling it straight up and out. Reassemble
by reversing steps.
CAUTION: Maintenance
DISASSEMBLY
1. Replacement parts may be available at the store where
you purchased your faucet.
2. When replacement parts are not available, please write or
call Price Pfister Consumer Service.
3. Always turn off water and relieve pressure before
working on your faucet.
NOTE: Trim Care
Cleaning Instructions:
For all handles and decorative finishes, use only a soft damp
cloth to clean and shine. Use of polish, detergents, abrasive
cleaners, organic solvents or acid may cause damage. Use
of other than a soft damp cloth will nullify our warranty!
Special Trim:
Trim products which contain porcelain or other similar
substance are not acceptable for public areas or Commercial
use. Installation of Said Trim is at Users Risk!
6 WATER SUPPLY LINES (Fig.B)
If necessary thread Adapter (2) into Faucet Inlets (1).
Connect water Supply Lines (3) to Faucet Inlets (1). Hot
water supply line goes to hot inlet fitting. (Supply lines
not included). Follow manufacturer’s instructions when
installing supply lines.
7 UNIT START UP
Turn on hot and cold water supplies, and check for leaks
above and below the sink.