7 TEMPERATURE KNOB ATTACHMENT

Lubricate the Cartridge O-Rings (7A) using provided Grease. Insert Knob

Assembly (7B) into Valve Body (7C) aligning the Cartridge Hole (7D) with

Valve Hole (7E). Secure Knob Assembly (7B) using Set Screw (7F).

Caution: Do not over tighten!

8 UNIT START UP

Turn on hot and cold water supplies, and check all connections for leaks.

9 VALVE FUNCTION

By rotating Temperature Knob (9A) clockwise, the water temperature will

decrease to fully cold. The water temperature can be increased by rotating

Temperature Knob (9A) counterclockwise.

The Temperature Knob (9A) is regulated for the water temperature not to to

exceed 100°F (38°C) to prevent burns. To increase the water temperature,

press Button (9B) and rotate the Temperature Knob (9A) in the counterclockwise

direction.

• Temperature or Flow does not remain constant

The Cartridge Assembly (10A) must be cleaned. Shut-off water supply.

Remove Set Screw (10B), and Knob Assembly (10C) from Valve Body (10D).

Inspect inlets for sediment and fl ush with water. Inspect O-Rings (10G) for

damage. Re-install Cartridge Assembly (10A), and turn on water supply. If

problem persists replace Cartridge Assembly (10A).

CAUTION: Do not disassemble Cartridge (10A).

• Dripping from either the tub spout or shower head.

Clean the Cartridge Assembly (10A). Check to ensure the two Oval O-Rings

(10G) on Cartridge (10A) are in place. Reassemble cartridge, and trim

assembly and handle. Turn on the water and test. If the unit still leaks, replace

the Cartridge.
• Make sure that both hot and cold water inlets are turned on.
• Water fl ow is very low.

Check the Cartridge Assembly (10A), for debris. Sediment where the water

enters the Shower Head can also cause this symptom.
• Water starts out cold and becomes hotter as handle is rotated clockwise.

This is a potentially hazardous situation and should be corrected before using

the unit. Check the hot and cold inlet positions (hot-left, cold-right).
• Water fl ows from the tub spout while using the shower.

The seal inside of the diverter mechanism may have become dislodged. The

Spout may need replacement.

CAUTION: Maintenance

DISASSEMBLY
1. Replacement parts may be available at the store where you purchased

your faucet.

2. When replacement parts are not available, please write or call Price

Pfi ster Consumer Service.

3. Always turn off water and relieve pressure before working on your

faucet.

NOTE: Trim Care

Cleaning Instructions:

For all Handles and decorative fi nishes, use only a soft damp cloth to clean

and shine. Use of polish, detergents, abrasive cleaners, organic solvents or

acid may cause damage. Use of other than a soft damp cloth will nullify

our warranty!

Special Trim:

Trim products which contain Porcelain or other similar substance are not

acceptable for public areas or Commercial use. Installation of Said Trim is

at Users Risk!

1–800–PFAUCET (1–800–732–8238)

For Toll-Free Pfaucet information call
1–800–PFAUCET (1–800–732–8238)
or visit www.pricepfi ster.com

• Installation Support
• Care and Warranty Information

3

FULL HOT

FULL COLD

7F

7B

7D

7E

7C

9A

9B

7A

10A

10D

10G

10E

10F

10C

10B