En g l is h english – Pfister GT526-TMS User Manual
Page 6
E
N
G
L
IS
H
ENGLISH
ENGLISH
25
23
24
CAUTION: Maintenance
DISASSEMBLY
1. Replacement parts may be available at the store where you purchased
your faucet.
2. When replacement parts are not available, please write or call Price
Pfi ster Consumer Service.
3. Always turn off water and relieve pressure before working on your
faucet.
NOTE: Trim Care
Cleaning Instructions:
For all Handles and decorative fi nishes, use only a soft damp
cloth to clean and shine. Use of polish, detergents, abrasive
cleaners, organic solvents or acid may cause damage. Use of
other than a soft damp cloth will nullify our warranty!
Special Trim:
Trim products which contain Porcelain or other similar
substance are not acceptable for public areas or Commercial
use. Installation of Said Trim is at Users Risk!
1–800–PFAUCET (1–800–732–8238)
For Toll-Free Pfaucet information call
1–800–PFAUCET (1–800–732–8238)
or visit www.pricepfi ster.com
• Installation Support
• Care and Warranty Information
23 PULL-OUT HOSE REMOVAL
To remove the quick connect attachment: Push up on the Quick Connector (23A).
Holding grey Plastic Colette (23B) in place, pull downward on Quick Connector (23A)
until Tube (23C) is free.
24 HANDLE REMOVAL
Carefully pry off Handle Button (24A). Using a
3
/
32
” Allen wrench, loosen Set Screw
(24B) and remove Handle (24C).
25 CARTRIDGE REPLACEMENT
Turn off water supplies and relieve pressure before working on your faucet.
Remove handle (see step 24). Remove the Dome Cap (25A) by unscrewing
counterclockwise. Using pliers, unscrew the retainer ring (25B). Carefully remove
the Cartridge (25C) by pulling it straight up and out. Reassemble valve by reversing
steps.
6
25C
23B
24B
23A
23C
23A
24A
24C
25B
25A