background image

Series 920

Series 920

Line Voltage

Input

Temp Range Control Mode

Action

Output

Set Point

Mounting

Retrofit

See Notes

Below

920A-4CD0-A000

115/230 VAC

Universal

Progammable

Progammable

Sw DC, 6A Relay

Profiling

1/4 DIN

F4SH-CKA0-01RG

3

920A-4CD0-B000

115/230 VAC

Universal

Progammable

Progammable

Sw DC, 6A Relay

Profiling

1/4 DIN

F4SH-CKA0-01RG

3, 16

920A-4DA0-A000

115/230 VAC

Universal

Progammable

Progammable

6A Relay, no output 2

Profiling

1/4 DIN

F4SH-KAA0-01RG

3

920A-4DA0-B000

115/230 VAC

Universal

Progammable

Progammable

6A Relay, no output 2

Profiling

1/4 DIN

F4SH-KAA0-01RG

3, 16

920A-4DB0-A000

115/230 VAC

Universal

Progammable

Progammable

6A Relay, 0.5A SSR

Profiling

1/4 DIN

F4SH-KKA0-01RG

3

920A-4DB0-B000

115/230 VAC

Universal

Progammable

Progammable

6A Relay, 0.5A SSR

Profiling

1/4 DIN

F4SH-KKA0-01RG

3, 16

920A-4DC0-A000

115/230 VAC

Universal

Progammable

Progammable

6A Relay, Sw DC

Profiling

1/4 DIN

F4SH-KCA0-01RG

3

920A-4DC0-B000

115/230 VAC

Universal

Progammable

Progammable

6A Relay, Sw DC

Profiling

1/4 DIN

F4SH-KCA0-01RG

3, 16

920A-4DD0-A000

115/230 VAC

Universal

Progammable

Progammable

6A Relay, 6A Relay

Profiling

1/4 DIN

F4SH-KKA0-01RG

3

920A-4DD0-B000

115/230 VAC

Universal

Progammable

Progammable

6A Relay, 6A Relay

Profiling

1/4 DIN

F4SH-KKA0-01RG

3, 16

920A-4EA0-A000

115/230 VAC

Universal

Progammable

Progammable

15A Triac, no output 2

Profiling

1/4 DIN

F4SH-CAA0-01RG

3

920A-4EA0-B000

115/230 VAC

Universal

Progammable

Progammable

15A Triac, no output 2

Profiling

1/4 DIN

F4SH-CAA0-01RG

3, 16

920A-4EB0-A000

115/230 VAC

Universal

Progammable

Progammable

15A Triac, 0.5A SSR

Profiling

1/4 DIN

F4SH-CKA0-01RG

3

920A-4EB0-B000

115/230 VAC

Universal

Progammable

Progammable

15A Triac, 0.5A SSR

Profiling

1/4 DIN

F4SH-CKA0-01RG

3, 16

920A-4EC0-A000

115/230 VAC

Universal

Progammable

Progammable

15A Triac, Sw DC

Profiling

1/4 DIN

F4SH-CCA0-01RG

3

920A-4EC0-B000

115/230 VAC

Universal

Progammable

Progammable

15A Triac, Sw DC

Profiling

1/4 DIN

F4SH-CCA0-01RG

3, 16

920A-4ED0-A000

115/230 VAC

Universal

Progammable

Progammable

15A Triac, Relay

Profiling

1/4 DIN

F4SH-CKA0-01RG

3

920A-4ED0-B000

115/230 VAC

Universal

Progammable

Progammable

15A Triac, Relay

Profiling

1/4 DIN

F4SH-CKA0-01RG

3, 16

920A-4FA0-A000

115/230 VAC

Universal

Progammable

Progammable

4-20MA, no output 2

Profiling

1/4 DIN

F4SH-FAA0-01RG

920A-4FA0-B000

115/230 VAC

Universal

Progammable

Progammable

4-20MA, no output 2

Profiling

1/4 DIN

F4SH-FAA0-01RG

16

920A-4FB0-A000

115/230 VAC

Universal

Progammable

Progammable

4-20MA, 0.5A SSR

Profiling

1/4 DIN

F4SH-FKA0-01RG

920A-4FB0-B000

115/230 VAC

Universal

Progammable

Progammable

4-20MA, 0.5A SSR

Profiling

1/4 DIN

F4SH-FKA0-01RG

16

920A-4FC0-A000

115/230 VAC

Universal

Progammable

Progammable

4-20MA, Sw DC

Profiling

1/4 DIN

F4SH-FCA0-01RG

920A-4FC0-B000

115/230 VAC

Universal

Progammable

Progammable

4-20MA, Sw DC

Profiling

1/4 DIN

F4SH-FCA0-01RG

16

920A-4FD0-A000

115/230 VAC

Universal

Progammable

Progammable

4-20MA, Relay

Profiling

1/4 DIN

F4SH-FKA0-01RG

3

920A-4FD0-B000

115/230 VAC

Universal

Progammable

Progammable

4-20MA, Relay

Profiling

1/4 DIN

F4SH-FKA0-01RG

3, 16

Note 1: Retrofit controller requires a substitution of a 100 Ohm DIN RTD sensor.
Note 2: Mounting and dimensions of retrofit controller are different. Verify that sufficient panel space and depth is available.
Note 3: Retrofit controller outputs are different. Add external interposing mechanical or solid state relay if applicable.
Note 4: Retrofit controller has a programmable, not fixed set point. Lock set point using controller's lockout parameter.
Note 5: For DIN rail mounting or sub-panel mounting, purchase DIN rail adapter p/n 0822-0586-P001 for 1/32 DIN or p/n 0822-0586-P002 for 1/16 DIN.
Note 6: Add a quencharc suppressor, Watlow p/n 0804-0147-0000, for inductive loads.
Note 7: Retrofit does not have equivalent action (as example, no manual reset)
Note 8: Retrofit controller does not have dual dial scale.
Note 9: Hardware lockout is not available on retrofit.
Note 10: Retrofit controller does not have user selectable line voltage.
Note 11: Retrofit does not support remote set point or retransmit. If wires are on these pins, select a different retrofit.
Note 12: Retrofit controller does not have user selectable control action.
Note 13: Solid state sensor required for humidity. See http://www.vaisala.com
Note 14: Retrofit controller does not have user selectable control mode.

Note 15: Use auxiliay event board A007-1732-F4B8

Note 16: Retrofit communications are different, consult specifications.

Note 17: Verify retrofit input range matches application.

Watlow Controls

4/27/2006

Page 3