-11-
Attaching an Arm
A commercially available arm or similar device that conforms to
VESA FPMPMI standards can be connected with the Unit's Rear
Cover.
Attach the Unit to the arm with the attachment screws.
The length of screws that can be used is limited.
With the Rear Cover, the screw depth is limited to 10
mm [0.39 in.] or less.
4
Cover Removal
Remove the Rear Cover from the Unit using the procedures de-
scribed below.
1) Remove the power supply cover and disconnect all power cord
terminals.
2) Use a slotted screwdriver to release the Rear Cover from the three
clips on the bottom face of the Unit.
To do this, insert a standard screwdriver into the clip positions
shown below, and lift up the Cover to release the Clip. Repeat for
each clip.
Cover the tip of the slotted screwdriver with a cloth or paper to
prevent the Unit's case from being damaged or scratched.
2) Adjust the screen angle.