FP3500-T41-24V/FP3600-T41-24V (Type DC)
Power Cable specification
Use copper conductors only.
Power connector specification
Use the following wiring for FP. Those are Phoenix Contact products.
Cable thickness
0.75~2.5mm
2
(18-12 AWG)
Core wire condition
Single or Stranded wire
*1
*1.
In case of using a strand wire, inappropriate twisting of the core wire
may cause short circuit between each wire, or between wire and the
abutting electrode contact.
Core wire length
+
24V
-
0V
FG
A frame ground terminal connected with FP unit
• Ensure that the power cable is twisted where it is near the
connector.
• Kind of power cord is GMVSTBW2,5/3-STF-7,62, which are
Phoenix Contact products.
Recommended Drivers
SZF 1-0.6×3.5(1204517)
Recommended stick end
terminal
AI 0.75-8GY (3200519)
AI 1-8RD (3200030)
AI 1.5-8BK (3200043)
AI 2.5-8BU (3200522)
Crimp tool for recommended
stick end terminal
CRIMPFOX ZA 3 (1201882)
7mm[0.28inch]
FG
-
+
Power Cable Joint