8
Serial Mode Select Switches (SW4 to SW10) operate as shown in the circuit diagram below.
*1
Refer to *2 on the previous page.
2.
Internal switches of the front module
Touch Panel Set Switch
Switch
Location
Switch Name
Factory
Settings
Description
SW1
Touch Panel
Set Switch
1:ON, 2:ON,
3:OFF, 4:OFF
4-point DIP switch. For Touch Panel Set Switch
details, see “ Touch Panel Set Switch”.
SW2
—
1:OFF, 2:OFF,
3:ON, 4:OFF
Internal setting.
Do not change. (Factory setting)
Switch
No.
Description
ON
OFF
Factory
Settings
Notes
1 to 2
Internal setting
Reserved Reserved
ON
Do not change.
(Factory setting)
3
OFF
4
Cancellation function
of two point touch on
the touch panel
*1
*1
When two points are pushed, it is considered that middle point between the two points is touched
according to the nature of the analog resistive touch panel. When the switch, etc. is set on the middle
point, it will be enabled and may operate. To prevent such a switch from malfunction in case of pushing
two points, turn ON the Switch No.4 in advance, then the middle point will be disabled for two point
touch.
Enabled
Disabled OFF
The middle point is not considered
to be touched when the switch is
ON. It is considered to be touched
when the switch is OFF.
*1
RT(RTS) Automatic
control
SW1
SW2
ON
ON
Rear face of the front module