Ce marking, Inquiry – Proface APL3000B - Node Box PC User Manual
Page 16
16
PL's Front Module
Notes:
1. Nonincendive Circuit Parameters:
Front USB I/F:
Voc = 5.0 V, Isc = 1.25 A, Ca = 10
µF,
La = 16
µH
2. Selected Associated Nonincendive Field
Wiring Apparatus shall satisfy the
following:
3. If the electrical parameters of the cable
are unknown, the following values may
be used:
Capacitance = 60pF/ft, Inductive = 0.20
µH/ft
4. Nonincendive Field Wiring must be
installed in accordance with article
501.10(B) of the National Electrical
Code ANSI/NFPA 70.
5. Nonincendive Field Wiring Apparatus
shall not contain or be connected to
another source of power.
CE Marking
• APL3900-TA unit is CE marked product
that conforms to EMC directives and Low
Voltage Directives.
• APL3900-TD unit is CE marked product
that conforms to EMC directives.
For the detailed information, be downloaded
and refer the Declaration of Conformity from
Pro-face Home Page.
Digital Electronics Corporation
8-2-52 Nanko-higashi
Suminoe-ku, Osaka 559-0031
JAPAN
TEL: +81-(0)6-6613-3116
FAX: +81-(0)6-6613-5888
http://www.pro-face.com/
The information in this document is subject to
change without notice.
© Copyright 2007 Digital Electronics
Corporation. All rights reserved.
PFX105924F .PL3900T-MT03E-BTH
2012.3 JM/E
Nonincendive Field
Wiring Apparatus
-
Front module
of PL unit
Voc
≤
Vmax
Isc
≤
Imax
Ca
≥
Ci+C cable
La
≥
Li+L cable
USB Pin Description
(See note 1 for detail)
Shield. Gnd
1.Vcc
2.D-
3.D+
4.GND
1
2
3
4
Nonincendive Field
Wiring Apparatus
Inquiry
Do you have any questions or
comments about this product?
Please access our site anytime you
need help with a solution.
http://www.pro-face.com/otasuke/
Please be aware that Digital Electronics
Corporation shall not be held liable by the
user for any damages, losses, or third
party claims arising from the uses of this
product.
Note