Internal switches of the control box – Proface APL3000B - Node Box PC User Manual
Page 6
6
1.
Internal switches of the control box
System Set Switch
Switch
Location
Switch Name
Compati-
ble I/F
Factory
Settings
Description
SW1
System Set Switch
–
See
10-point DIP switch. For System Set
Switch and the factory settings
details, see
SW2
Serial Mode Select
Switch
COM1
All OFF
(RS-232C)
10-point DIP switch. Designates
COM1 communication settings. For
Serial Mode Select Switch details,
see
SW3
CI(RI)/+5V
Changeover Switch
COM2
CI(RI)
Changes # 9 pin (CI(RI) / +5V).
SW4
CI(RI)/+5V
Changeover Switch
COM1
CI(RI)
Changes # 9 pin (CI(RI) / +5V).
Switch
No.
Description
ON
OFF
Factory
Settings
Notes
1
Internal setting
Reserved Reserved OFF
Do not change.
(Factory setting)
2
Implements the
logical inversion
operation for
RAS output
Normal
Close
Normal
Open
OFF
RAS output is a CLOSE state when the
switch and the system is ON. When the
Switch is OFF, it is the opposite. The
RAS Output keeps Normal OPEN
when the Soft OFF state occurs or the
power turns OFF.
3
Sets up an
enabled/disabled
state for the front
USB port execution
control function
*1
*1
The Setting up an enabled/Disabled state for USB port execution control function is available for
only Windows
®
2000 and Windows
®
XP. Make sure to disable the function of the setting when
other OS is used.
Enabled Disabled ON
The front USB port is available when
the switch is ON. It is unavailable when
the switch is OFF.
4
Internal setting
Reserved Reserved
OFF
Do not change.
(Factory setting)
5 to 8
ON
9 to 10
OFF
1 10
1 10
SW4
SW1
SW2
SW3
OFF
ON
ON
OFF
Bottom face of the control box
(CI)RI
5V