Introduction to o, General o, Specifications – Progressive International Electronics Omega2 User Manual
Page 6

O
MEGA
2/O
MEGA
Lite Universal Site Interface
Installation Guide
Version 1.0
October 2011
Page 2
O
MEGA
2
AND
O
MEGA
L
ITE
USI
Introduction to O
MEGA
The O
MEGA
is a universal site controller designed with flexibility in mind. The O
MEGA
2 and
O
MEGA
Lite both have the ability to connect to POS devices/applications and to dispensers
and their associated card readers. We refer to the POS connectivity as the “front end” and
the part of the O
MEGA
that connects to the dispensers as the “pump side.”
On the front end, both O
MEGA
versions are designed to connect to a POS, such as a
VeriFone Ruby system, and run various brands of dispensers. Both versions use the PAM
1000 protocol to control the dispensers. The pump side is capable of running up to three
brands of dispensers (both domestic and foreign) at the same time.
O
MEGA
Lite – A direct replacement for the PAM 1000. It connects to a POS, such as
VeriFone, on Port 4 and to the Gilbarco TW Universal DBox(es). It can run up to 36
fueling positions when using all three ports (Ports 1, 2 and 3).
O
MEGA
2 – PAM 1000 replacement, enhanced with its own built-in DBox boards. These
boards control a variety of dispensers, as well as a card reader, eliminating the need for a
B&B box. The O
MEGA
2 can also connect to price signs (up to two brands at the same
time) and a tank gauge system, such as Veeder-Root, to do reconciliation.
General O
MEGA
Specifications
Operating Temperature
32 to 120 degrees F
Storage Temperature
32 to 120 degrees F
Humidity
50 to 90% non-condensing
Electrical Supply
115VAC, 100 watts maximum dedicated circuit with earth bond
Size
O
MEGA
Lite – 14" x 10" x 4"
O
MEGA
2 – 14" x 14" x 5.875"
Safety Certifications
MET labs US, CA CE
Note: The O
MEGA
power supplies may be line voltage selectable. All units are shipped from
factory set for 115 VAC operation. Ensure that the selector switch on the front panel is set for
115 VAC operation.