beautypg.com

Cautions and warranty, Accessories, Cautions – Ross Controls RIGHT ANGLE User Manual

Page 19: Standard warranty, Extra port blocks, Male and female end ports

background image

www.rosscontrols.com 19

Extra Port Blocks

An extra port block can be placed between

modules to provide two auxiliary 1/4 NPTF ports.

Its mounting position can be rotated to obtain the

most convenient operating orientation. If only

one auxiliary port is to be used, the unused port

must be closed with a pipe plug. (The inlet and
outlet are not threaded.)
Port Size

Part Number*

1/4 NPTF

R-118-106-2

3/8 NPTF

R-118-106-3

1/2 NPTF

R-118-106-4

For BSPP threads, add a “W” suffix to the model number,
e.g., R-118-109-2FW.

Male and Female End Ports

Either male or female end ports can be

attached to threaded inlet and outlet

lines. This allows all modules of an FRL

assembly to be removed easily and

quickly without having to unthread the end

modules. The end ports are attached to the modules with clamps (see

at left). End ports can be included in an assembled FRL or ordered
separately by the following part numbers:
Port Size

Male Part Number* Female Part Number*

1/4 NPTF

R-118-109-2F

R-118-100-2

3/8 NPTF

R-118-109-3F

R-118-100-3

1/2 NPTF

R-118-109-4F

R-118-100-4

3/4 NPTF

R-118-109-6F

R-118-100-6

For BSPP threads, add a “W” suffix to the model number,
e.g., R-118-109-2FW.

PRE-INSTALLATION or SERVICE
1. Before servicing a valve or other pneumatic component, be sure

that all sources of energy are turned off, the entire pneumatic system

is shut off and exhausted, and all power sources are locked out (ref:

OSHA 1910.147, EN 1037).
2. All ROSS products, including service kits and parts, should

be installed and/or serviced only by persons having training and

experience with pneumatic equipment. Because any installation

can be tampered with or need servicing after installation, persons

responsible for the safety of others or the care of equipment must

check every installation on a regular basis and perform all necessary

maintenance.
3. All applicable instructions should be read and complied with before

using any fluid power system in order to prevent harm to persons

or equipment. In addition, overhauled or serviced valves must be

functionally tested prior to installation and use.
4. Each ROSS product should be used within its specification limits. In

addition, use only ROSS parts to repair ROSS products. Failure to follow

these directions can adversely affect the performance of the product or

result in the potential for human injury or damage to property.
FILTRATION and LUBRICATION
5. Dirt, scale, moisture, etc. are present in virtually every air system.

Although some valves are more tolerant of these contaminants than

others, best performance will be realized if a filter is installed to clean

the air supply, thus preventing contaminants from interfering with the

proper performance of the equipment. ROSS recommends a filter

with a 5-micron rating for normal applications.
6. All standard ROSS filters and lubricators with polycarbonate plastic

bowls are designed for compressed air applications only. Do not fail

to use the metal bowl guard, where provided, to minimize danger from

high pressure fragmentation in the event of bowl failure.

Do not expose these products to certain fluids, such as alcohol or

liquefied petroleum gas, as they can cause bowls to rupture, creating

a combustible condition, hazardous leakage, and the potential for

human injury or damage to property. Immediately replace a crazed,

cracked, or deteriorated bowl. When bowl gets dirty, replace it or wipe

it with a clean dry cloth.
7. Only use lubricants which are compatible with materials used in

the valves and other components in the system. Normally, compatible

lubricants are petroleum based oils with oxidation inhibitors, an aniline

point between 180°F (82°C) and 220°F (104°C), and an ISO 32, or

lighter, viscosity. Avoid oils with phosphate type additives which can

harm polyurethane components, potentially leading to valve failure

which risks human injury, and/or damage to property.
AVOID INTAKE/EXHAUST RESTRICTION
8. Do not restrict the air flow in the supply line. To do so could reduce

the pressure of the supply air below the minimum requirements for

the valve and thereby cause erratic action.
9. Do not restrict a valve’s exhaust port as this can adversely affect its

operation. Exhaust silencers must be resistant to clogging and must

have flow capacities at least as great as the exhaust capacities of

the valves. Contamination of the silencer can result in reduced flow

and increased back pressure.
ROSS expressly disclaims all warranties and responsibility for any

unsatisfactory performance or injuries caused by the use of the wrong

type, wrong size, or an inadequately maintained silencer installed

with a ROSS product.
ENERGY ISOLATION/EMERGENCY STOP
11. Per specifications and regulations, ROSS

L-O-X

®

valves and

L-O-X

®

valves with

EEZ-ON

®

operation are defined as energy isolation

devices, NOT AS EMERGENCY STOP DEVICES.

CAUTIONS

Accessories

Female

Male

All products sold by ROSS CONTROLS are warranted for a one-year period [with the exception
of all Filters, Regulators and Lubricators (“FRLs”) which are warranted for a period of seven
years] from the date of purchase to be free of defects in material and workmanship. ROSS’

obligation under this warranty is limited to repair or replacement of the product or refund of the purchase price paid solely at the discretion of ROSS
and provided such product is returned to ROSS freight prepaid and upon examination by ROSS is found to be defective. This warranty becomes void
in the event that product has been subject to misuse, misapplication, improper maintenance, modification or tampering.
THE WARRANTY EXPRESSED ABOVE IS IN LIEU OF AND EXCLUSIVE OF ALL OTHER WARRANTIES AND ROSS EXPRESSLY DISCLAIMS ALL
OTHER WARRANTIES EITHER EXPRESSED OR IMPLIED WITH RESPECT TO MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
ROSS MAKES NO WARRANTY WITH RESPECT TO ITS PRODUCTS MEETING THE PROVISIONS OF ANY GOVERNMENTAL OCCUPATIONAL
SAFETY AND/OR HEALTH LAWS OR REGULATIONS. IN NO EVENT IS ROSS LIABLE TO PURCHASER, USER, THEIR EMPLOYEES OR OTHERS
FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES WHICH MAY RESULT FROM A BREACH OF THE WARRANTY DESCRIBED ABOVE OR THE
USE OR MISUSE OF THE PRODUCTS. NO STATEMENT OF ANY REPRESENTATIVE OR EMPLOYEE OF ROSS MAY EXTEND THE LIABILITY
OF ROSS AS SET FORTH HEREIN.

STANDARD WARRANTY

This manual is related to the following products: