Ultraw a ve micr o bts, Ultrawave micro bts, Gsm base transceiver station – ADC UltraWave Micro BTS User Manual
Page 3: Specifications

6/08
•
106405AE
UltraW
A
VE
Micr
o
BTS
UltraWAVE Micro BTS
GSM Base Transceiver Station
3
w w w . a d c . c o m
•
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
•
1 - 8 0 0 - 3 6 6 - 3 8 9 1
Specifications
BTS Configurations (single cabinet): S111, S222, O4, O6
Frequency Support:
GSM 850 MHz, GSM 900 MHz, DCS 1800 MHz, PCS 1900 MHz
CapaCiTy
Number of TRXs:
6
Number of Traffic Channels:
44
Traffic Capacity:
34.68 Erlangs @ 2% GoS (O6)
1380 subscribers @ 25mE
Output power:
50 Watts (antenna port)
RF Receiver Sensitivity:
-111 dBm without diversity
-114 dBm with diversity
iNTeRFaCeS
RF interface:
GSM Compliant Um Interface; GSM spec. 04.06, 04.08, 05.01- 05.05,
05.08 & 05.10; GSM spec 03.64, 04.60 (Rel 98)
BSC Link:
Abis Interface, GSM spec. 04.08, 08.58, 12.21
Transmission:
Dual Port G7.03 compliant E1 75/120 Ohm;
Dual Port T1.403 compliant T1 100 Ohm
ethernet:
10/100 Mbps Ethernet, RJ-45 connector
Serial port:
RS232, RJ-45 connector
OpeRaTiON
Remote Monitoring:
Monitor temperature, PA, fan, PSU, VWSR from central office;
External alarms supported
Overtemp protection:
Automatic detection and intervention
access to equipment:
Front and rear access
Field Support:
All modules are field replaceable
Capacity expansion:
Field upgradable
Support of various upgrades
pOweR SuppLy
input Voltage:
110/220 VAC, -48 VDC
Redundancy:
Redundant power supply
alarm:
PSU failure alarm reported to OMC
MeChaNiCaL
Rack Mount:
Versatile mounting options for 19", 23" and 24" racks
Dimensions (hxwxD):
1051 x 560 x 647 mm (41.8 x 22.05 x 25.5 inches)
weight:
213 kg (470 lbs)
OpeRaTiNg eNViRONMeNT
Temperature:
-5° to 55° C (23° to 131° F)
humidity (non-condensing):
10% to 90%