Performance, Re2 performance, Determined by actual flow meter tests – Versa-Matic 2 Bolted Metallic Ball Valve Pumps (RE2) User Manual
Page 6: Re2 bolted - aluminum, Re2 bolted - metallic, Pump specs
Performance
RE2 Bolted - Aluminum
Flow Rate
Adjustable to . . . . . . . 0-155 gpm (587 lpm)
Port Size
Suction . . . . . . . . . . . . . . . . . . 2" NPT (BSP)
Discharge. . . . . . . . . . . . . . . . 2" NPT (BSP)
Air Inlet . . . . . . . . . . . . . . . . . . . . . . . 1" NPT
Air Exhaust . . . . . . . . . . . . . . . . . . 3/4" NPT
Suction Lift
Dry . . . . . . . . . . . . . . . . . . . . . . .20' (6.10 m)
Wet. . . . . . . . . . . . . . . . . . . . . . .25' (7.6 2m)
Suction Lift (PTFE)
Dry . . . . . . . . . . . . . . . . . . . . . . .10' (3.05 m)
Wet. . . . . . . . . . . . . . . . . . . . . . .20' (6.10 m)
Max Solid Size (Diameter)
. . . . . . . . . . . . . . . . . . . . . . . .0.43" (11 mm)
Max Noise Level . . . . . . . . . . . . . 92 dB(A)
Shipping Weights
Aluminum . . . . . . . . . . . . . . .77.5 lbs (35 kg)
RE2 Bolted - Metallic
Flow Rate
Adjustable to . . . . . . . 0-150 gpm (568 lpm)
Port Size
Suction . . . 2" ANSI 150#
(DIN 50 Compatible Flange)
Discharge. 2" ANSI 150#
(DIN 50 Compatible Flange)
Air Inlet . . . . . . . . . . . . . . . . . . . . . . . 1" NPT
Air Exhaust . . . . . . . . . . . . . . . . . . 3/4" NPT
Suction Lift
Dry . . . . . . . . . . . . . . . . . . . . . . .20' (6.10 m)
Wet. . . . . . . . . . . . . . . . . . . . . . .25' (7.62 m)
Suction Lift (PTFE)
Dry . . . . . . . . . . . . . . . . . . . . . . .10' (3.05 m)
Wet. . . . . . . . . . . . . . . . . . . . . . .20' (6.10 m)
Max Solid Size (Diameter)
. . . . . . . . . . . . . . . . . . . . . . . .0.43" (11 mm)
Max Noise Level . . . . . . . . . . . . . 92 dB(A)
Shipping Weights
Stainless/Cast Iron. . . . . . .125.5 lbs (57 kg)
Hastelloy C. . . . . . . . . . . . . . 137 lbs (62 kg)
re2mdlAsm-rev0314
www
.
versamatic
.
com
1: PUMP
SPECS
3
• Model RE2 Metallic Bolted
CAUTION:
Do not exceed 125 psig (8.5 bar) air supply or liquid pressure.
NOTE: For RE2AA pumps fitted with PTFE diaphragms, reduce water discharge figures by 10%.
Suction lift is reduced to 10' (3.05m) dry and 20' (6.10m) wet.
CAUTION: Do not exceed 125 psig (8.5 bar) air supply or liquid pressure.
NOTE: For RE2SA pumps fitted with PTFE diaphragms, reduce water discharge figures by 10%.
Suction lift is reduced to 10' (3.05m) dry and 20' (6.10m) wet.
0
0
50 100 150 200 250 300 350 400 450 500 550 600 650
100
110
120
130
90
80
70
60
50
40
30
20
10
0
10
30
50
70
90
110
130
150
170
Discharge Pressure in PSI
Flow in U.S. Gallons Per Minute
Flow in Liters Per Minute
Meters Feet
0
0
40
80
120
160
200
240
280
10
20
30
40
50
60
80
90
70
0
1
2
3
4
5
6
7
8
9
BAR
Displacement Per Stroke, 0.60 Gal. (2.33 L)
20 30
40
50
60
70
SCFM M
3
/HR
10 17
20 34
30 51
40 68
50 85
60 102
70 119
80 136
90 153
100 170
AIR CONSUMPTION IN SCFM
AIR PRESSURE IN PSI
125 PSI (
8.6 BAR
)
100 PSI (6.8 B
AR)
80 PSI (5.44
BAR)
60 PSI (4.08 B
AR)
40 PSI (2.72 B
AR)
20 PSI (1.36 BAR)
NOTE: For RE2AA pumps fitted with PTFEdiaphragms, reduce water discharge figures by 20%.
Suction lift is reduced to 10' (3.05m) dry and 20' (6.10m) wet.
CAUTION:Do not exceed 125 psig (8.5 bars) air supply or liquid pressure.
0
100
200
300
400
500
75
70
65
60
55
50
45
40
35
30
25
20
15
10
5
0
240
220
200
180
160
140
120
100
80
60
40
20
0
600
Meters Feet
Capacity in Liters Per Minute
Capacity in U.S. Gallons Per Minute
Displacement Per Stroke, 0.50 Gal. (1.89 L)
RE2
PERFORMANCE
Determined by actual flow meter tests.
0
20
40
60
80
100
120
140
160
100
90
80
70
60
50
40
30
20
10
0
HEAD in PSI
100 PSI
(6.8 Bar)
70
SCFM M
3
/HR
10 17
20 34
30 51
40 68
50 85
60 102
70 119
30
50
130
120
110
300
280
260
90
85
80
80
60
40
20
125 PSI (8.6 Bar)
80 PSI (5.44 Bar)
60 PSI (4.08 Bar)
40 PSI (2.72 Bar)
20 PSI (1.37 Bar)
AIR CONSUMPTION IN SCFM