Airvantage troubleshooting guide – Versa-Matic 2 Bolted Metallic Ball Valve Pumps (RE2) User Manual
Page 12
re2mdlAsm-rev0314
www
.
versamatic
.
com
2: INST
AL
& OP
9
• Model RE2 Metallic Bolted
Caution! Whenever troubleshooting or performing any
repairs on any IDEX AODD equipment, always remove air
supply line to the pump and wear proper personal protec-
tive equipment.
lEd OuTPuT fOR airVantage uNIT
STATE
LED OUTPUT
Startup/Settle/Deadhead Solid
Standby/Low Flow
1 Second ON / 1 Second OFF
Learn Mode
0.1 Seconds ON / 0.1 Seconds OFF
Seek/Optimize
1 Second ON / 0.1 Seconds OFF
Steady State/Air Savings OFF / ON in rhythm with Cycle
Rate of Pump
airVantage lEd dOES NOT lIGHT uP aT all
What to Check:
• Make sure power switch on the control module is turned
on, (depressed to the left)
• Make sure air is being supplied to pump or make sure 110
VAC unit has power being supplied to it
Corrective Action:
• Cycle power switch off/on
• Unplug patch cable and cycle power switch off/on
• Consult Factory After Sales Support team
airVantage lEd lIGHTS uP aNd STayS ON SOlId
What to Check:
• Make sure patch cable is plugged in and locked
Corrective Action:
• Consult Factory After Sales Support team
ValVE fIRES ONCE aNd ImmEdIaTEly RESETS
Corrective Action:
• Consult Factory After Sales Support team
ValVE lEd NEVER lEaVES SEEK mOdE - airVan-
tage lEd PulSING IN TImE TO PumP, BuT ValVE
NOT aCTuaTING aNd THE PumP IS NOT SaVING
aIR
Corrective Action:
• Consult Factory After Sales Support team
uNExPECTEd OPERaTING CONdITION (aIR SaV-
INGS OR flOw RaTE)
What to Check:
• Check for varying environmental pumping conditions
(changing head or suction)
• Check ice buildup in exhaust area
• Inspect sleeve and spool for damage
Corrective Action:
• Consult Factory After Sales Support team
PumP CyClING IS uNSTaBlE OR ERRaTIC
What to Check:
• Run pump without AirVantage and check pump operation
• Make sure patch cable plug is connected and locked
• Make sure power wire connectors are tight
Corrective Action:
• Consult Factory After Sales Support team
PumP RuNNING SlOwly
What to Check:
• Run pump without AirVantage and check operation
• Cycle the power off/on to the control module to
reset controller
• Check ice buildup in exhaust area
• Inspect sleeve and spool set for damage
Corrective Action:
• Consult Factory After Sales Support team
• Cycle the power switch on the control module off/on
airVantage Troubleshooting Guide