• Model RE2 Metallic Bolted

Caution! Whenever troubleshooting or performing any

repairs on any IDEX AODD equipment, always remove air

supply line to the pump and wear proper personal protec-

tive equipment.

lEd OuTPuT fOR airVantage uNIT

STATE

LED OUTPUT

Startup/Settle/Deadhead Solid

Standby/Low Flow

1 Second ON / 1 Second OFF

Learn Mode

0.1 Seconds ON / 0.1 Seconds OFF

Seek/Optimize

1 Second ON / 0.1 Seconds OFF

Steady State/Air Savings OFF / ON in rhythm with Cycle

Rate of Pump

airVantage lEd dOES NOT lIGHT uP aT all

What to Check:

• Make sure power switch on the control module is turned

on, (depressed to the left)

• Make sure air is being supplied to pump or make sure 110

VAC unit has power being supplied to it

Corrective Action:

• Cycle power switch off/on

• Unplug patch cable and cycle power switch off/on

• Consult Factory After Sales Support team

airVantage lEd lIGHTS uP aNd STayS ON SOlId

What to Check:

• Make sure patch cable is plugged in and locked

Corrective Action:

• Consult Factory After Sales Support team

ValVE fIRES ONCE aNd ImmEdIaTEly RESETS

Corrective Action:

• Consult Factory After Sales Support team

ValVE lEd NEVER lEaVES SEEK mOdE - airVan-

tage lEd PulSING IN TImE TO PumP, BuT ValVE

NOT aCTuaTING aNd THE PumP IS NOT SaVING

aIR

Corrective Action:

• Consult Factory After Sales Support team

uNExPECTEd OPERaTING CONdITION (aIR SaV-

INGS OR flOw RaTE)

What to Check:

• Check for varying environmental pumping conditions

(changing head or suction)

• Check ice buildup in exhaust area

• Inspect sleeve and spool for damage

Corrective Action:

• Consult Factory After Sales Support team

PumP CyClING IS uNSTaBlE OR ERRaTIC

What to Check:

• Run pump without AirVantage and check pump operation

• Make sure patch cable plug is connected and locked

• Make sure power wire connectors are tight

Corrective Action:

• Consult Factory After Sales Support team

PumP RuNNING SlOwly

What to Check:

• Run pump without AirVantage and check operation

• Cycle the power off/on to the control module to

reset controller

• Check ice buildup in exhaust area

• Inspect sleeve and spool set for damage

Corrective Action:

• Consult Factory After Sales Support team

• Cycle the power switch on the control module off/on

airVantage Troubleshooting Guide