beautypg.com

Airvantage troubleshooting guide, Inst al & op – Versa-Matic 2 Bolted Metallic Ball Valve Pumps (RE2) User Manual

Page 13

background image

re2mdlAsm-rev0314

www

.

versamatic

.

com

2: INST

AL

& OP

Model RE2 Metallic Bolted •

10

airVantage Troubleshooting Guide

airVantage RESETS aNd ENTERS lEaRN mOdE

TOO fREQuENTly

What to Check:

• Check for excessive varying environmental pumping

conditions

(changing head or suction)

• Check ice buildup in exhaust area

• Inspect sleeve and spool for damage

• Make sure patch cable plug is connected and locked

Corrective Action:

• Consult Factory After Sales Support Team

PumP STallS, RESETS, lEaRNS, SEEKS aNd

REPEaTS

What to Check:

• Make sure patch cable plug is connected and locked

• Check ice buildup in exhaust area

Corrective Action:

• Consult Factory After Sales Support Team

PumP mOVES OuT Of STEady STaTE aNd NEVER

aTTEmPTS TO RElEaRN (lEd ON)

What to Check:

• Make sure patch cable plug is connected and locked

• Cycle the power off/on to the control module

Corrective Action:

• Consult Factory After Sales Support Team

• Cycle the power switch on the control module off/on

wHaT TO dO IN THE EVENT Of a dIaPHRaGm

faIluRE

If a diaphragm failure has been detected in pumps fitted

with AirVantage,

see page 5 for shut-down procedure.

What to Check:

• Has product migrated to the sensor?

Corrective Action:

• If the sensor has been submerged in product, the sensor

will need to be replaced. Consult the AirVantage servicing

section of the manual for detailed instructions.

What to Check:

• Has product contaminated the check valve cartridge?

Correct Action:

• If a significant amount of product has made it into the

check valve assembly, then the unit will need to be disas-

sembled for inspection. If the check valve assembly is dam-

aged, then it will need to be replaced. Consult parts list for

information.

VALVE, POPPET

VALVE, SOLENOID

CAPSCREW, HEX SOC HD, 10-32 X .50

COVER

SEAL, O-RING

SEAL, O-RING

MUFFLER

SEAL, O-RING

ASSEMBLY, POWER GENERATOR

CAPSCREW, HEX SOC HD, 10-32 X 2.25

SEAL, O-RING

CAPSCREW, HEX SOC HD, 10-32 X 1.00

CAPSCREW, HEX SOC HD, 10-32 X .50

O-RING

O-RING

CONTROL MODULE

REGULATOR