Rapid-Air CABINET REEL WITH DISPLAY KEYPAD User Manual
Page 16

16
1. AC Line Fuse is chosen according to the maximum rating of the control: 
 12 AMP fuse for all motors up to 3/4 HP-90V and 1 1/2 HP-180VDC. 
 25 AMP fuse for all motors 1 and 1 1/2 HP-90v and 2 and 3 HP-180VDC. 
 (Use Buss ABC, Little fuse 326 ceramic fuse or equivalent.) 
 
2. Armature Fuse can be chosen in accordance with the fuse chart. Note: The armature fuse is 
calculated based on the approximate full load DC current rating of the motor times a from 
factor of 1.5. If motor has characteristics not consistent with these approximations, a differ-
ent fuse value may have to be used. Fuses are available from your distributor. 
 
 
TABLE 4. ARMATURE FUSE CHART 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
ADJUSTMENTS AND CONTROL FUNCTIONS
 
 
 
The RAMM has been factory adjusted to provide 0-full speed using the speed control knob. 
Minimum and Maximum speed trim pots are provided to change the speed from other than 0-
full speed. The Acceleration (ACCEL) trim pot is provided to allow for a smooth start over an 
adjustable time period each time the AC power is applied or the speed pot is rotated. The DE-
CEL trim pot controls the amount of ramp-down when the speed pot is adjusted to a lower 
speed. The Current Limit (CL, or torque output) adjustment is factory set to approximately 1 
1/2 times the motor rating. The IR Compensation (IR) is factory adjusted to provide excellent 
motor regulation under normal operation.
WARNING: If adjustments are made under power, insulated adjustment 
tools must be used and eye protection must be worn. 
90VDC 180VDC 
MOTOR MOTOR 
 
HORSEPOWER 
 APPROX. 
 DC MOTOR 
 CURRENT 
 (AMPS) 
 
 FUSE 
 RATING 
 (AC AMPS) 
1/4 1/2 
1/2 1 
3/4 1 1/2 
1 2 
1 1/2 3 
 2.5 
 5.0 
 7.5 
 10.0 
 15.0 
 4 
 8 
 12* 
 15 
 25* 
 
*Also used as AC line Fuse. 