Rapid-Air CABINET REEL WITH DISPLAY KEYPAD User Manual
Page 11

11
5. Percent speed function set too low. 
 a. Adjust percent speed function to 100%. 
6. Fuses blown. 
 a. Check fuses & circuit breaker. 
7. No AC voltage at DC drive board. 
 a. Check wiring. 
8. Check Signal voltage between P2 to P1 on DC drive. 
 0-6 VDC—Ramm 
 0-9 VDC—Regen Drive 
 while moving dancer arm. 
 a. If there is a signal, check continuity between I1 & I2. 
 If no continuity, replace D.C. drive or call factory. 
10. Check pico fuse on 69100804 board (F1). 
 a. Replace fuse, 1 amp pico fuse—call factory. 
 