Troubleshooting, Fault code, Status led value fault meaning – Rapid-Air SERVO FEED: 100C, 100D series User Manual
Page 20

0
(Predefined Variable, Integer, Status Variable, Read-Only)
Guidelines -0 means the drive is not faulted and not enabled, while 8 means the drive is not faulted and enabled.
Alternating 8.> means actively inhibiting CW motion and alternating 8.< means actively inhibiting CCW motion
TROUblEShOOTING
Fault Code
(Blinking) 1
(Blinking) 2
(Blinking) 3
(Blinking) 4
(Blinking) 5
(Blinking) 6
(Blinking) 7
(Blinking) 9
(Blinking) A
(Blinking) b
(Blinking) C
(Blinking) D
(Solid) E*
(Blinking) E*
(Alternating) E1
(Alternating) E2
(Alternating) E3
(Alternating) E4
(Alternating) E5*
(Alternating) E6
(Alternating) E7
(Alternating) F1
(Alternating) F3
Status LED Value Fault Meaning
1
2
3
4
5
6
7
9
10
11
12
13
14
14
225
226
227
228
229
230
231
241
243
Velocity feedback (VelFB) over speed
Motor Over-Temp
Drive Over-Temp
Drive l*t
1-n Fault (9x3)
Control ±12 V supply under voltage
Output over current or bus over voltage
Not Assigned
Bus OV detected by DSP
Auxiliary ±5V Low
Not assigned
Not assigned
Processor throughput fault
Power Up Self Test Failure
Bus UV, Bus Voltage VBUSTHRUSH
Ambient Temp Too Low
Encoder commutation align failed (Only CommSrc=1)
Drive software incompatible with NV memory version
Control Card hardware not compatible with drive software version
Drive transition from unconfigured to configured while enabled
Two AlnNull events too close together
Excessive Position Following Error
Parameter Checksum Error (Memory Error)
* FaultReset cannot reset these faults.
See ExtFault for further information on Blinking E, Blinking 1 and Alternating F3.