Quick freeze, hard chill, soft chill, Manual operation, Factory default set points – Alto-Shaam QC2-3 User Manual
Page 20

Q U I C K C H I L L E R • I N S T A L L A T I O N / O P E R A T I O N / S E R V I C E M A N U A L • 1 8 .
S U b T I T l e
T I T l e
ManUal operaTIon
1.
Starting from the
off
position, press the
power key
on
.
The Alto-Shaam name will illuminate and the
SelecTIon Screen will appear on the display. The
compressor will become energized and will begin
to operate if required by the sensors.
2. Press the desired mode key.
The display will give an overview of the current
set-temperatures for the mode.
If the current settings are acceptable,
press the STarT/STop key to begin your
chill cycle.
If modifications are required, press the
proGraM key and proceed to step 3.
3. The display will require the operator to select
between chilling by probe or by TIMe.
Select the desired chill method (time or probe) by
pressing the right
4
or left
3
arrow keys.
Press the proGraM key to continue.
3a. If TIMe was selected, use the right
4
or left
3
arrow keys to highlight chill, hold, or time,
then press the up
5
or down
6
arrow keys to
change accordingly.
3b. If probe was selected, select top, middle and
lower probe using right
4
or left
3
arrow keys
and then press the up
5
or down
6
arrow keys to
change accordingly.
notE: QC2-3 and QC2-20 will display only
one probe.
4.
Once the desired settings are entered, press
the STarT/STop key to begin chilling.
chilling by Time
When chilling by time, the display will indicate
a count-down of the time, the air temperature,
and the temperature of each food probe. After
time has expired, the chiller will automatically
convert to the set holding mode.
chilling by probe
When chilling by probe, the display will indicate
the length of time the product has been chilling,
the interior compartment set temperature,
and the air temperature. The display will also
indicate the temperature of each probe along
with “
act
.” to advise the operator that the
individual probe is active. As each probe reaches
the set point value, the display will indicate
“
done
.” When all probes reach the individual set
point value, the chiller will automatically convert
to the holding mode.
note: When a removable probe is unplugged,
it is assumed to be at the set-point, and it will
display “
unplugged
” on the display instead of
the actual and temperature set points.
When In The holD TeMp MoDe afTer chIllInG by
probe:
Press the rIGhT
4
or lefT
3
arrow key to display the
length of time it took for each probe to achieve set
temperature.
these
data
are
retained
until
a
new
probe
cycle
is
completed
.
facTory DefaUlT SeT poInTS
QUIck freeZe, harD chIll, SofT chIll
a D v a n c e D o p e r a T I o n
o p e r a T I o n
Quickchiller >
Default Set points
preset
Mode
chill
probe
hold
1.
Beans
Hard Chill
14°F
38°F
38°F
2.
Beef
Hard Chill
14°F
38°F
38°F
3.
Casserole
Hard Chill
14°F
38°F
38°F
4.
Chicken Breast
Soft Chill
34°F
38°F
38°F
5.
Chicken Whole Hard Chill
14°F
38°F
38°F
6.
Duck
Hard Chill
14°F
38°F
38°F
7.
Fish
Soft Chill
34°F
38°F
38°F
8.
Ground Meat
Hard Chill
14°F
38°F
38°F
9.
Lamb
Hard Chill
14°F
38°F
38°F
10.
Lasagna
Hard Chill
14°F
38°F
38°F
11.
Pork
Hard Chill
14°F
38°F
38°F
12.
Potatoes
Hard Chill
14°F
38°F
38°F
13.
Rice
Hard Chill
14°F
38°F
38°F
14.
Sauce
Hard Chill
14°F
38°F
38°F
15.
Sheet Cake
Soft Chill
34°F @ 10 min.
—
38°F
16.
Soup
Hard Chill
14°F
38°F
38°F
17.
Stew
Hard Chill
14°F
38°F
38°F
18.
Stuffing
Hard Chill
14°F
38°F
38°F
19.
Turkey
Hard Chill
14°F
38°F
38°F
20.
Vegetables
Soft Chill
34°F
38°F
38°F