Alto-Shaam QC2-3 User Manual
Page 19

Q U I C K C H I L L E R • I N S T A L L A T I O N / O P E R A T I O N / S E R V I C E M A N U A L • 1 7 .
Q U I C K C H I L L E R • I N S T A L L A T I O N / O P E R A T I O N / S E R V I C E M A N U A L • 1 7 .
S U b T I T l e
T I T l e
c a u t i o n
ADEQUATE SPACING MUST
BE ALLOWED BETWEEN PANS
FOR PROPER AIR CIRCULATION
FOR BOTH PROCESSING AND
SUBSEQUENT HOLDING.
a D v a n c e D o p e r a T I o n
o p e r a T I o n
The date and time will appear in the display when
the unit is off. When the unit is turned on, the
screen will read: “SelecT MoDe or preSS STarT To
SelecT preSeT”
To initiate any Quickchiller operating mode,
power must initially start from the
off
position
or an operating mode must be halted by pressing
the STarT/STop key so that the SelecTIon Screen
appears on the display.
noTe: With the exception of the QC2-3 counter top
Quickchiller model, the Alto-Shaam name on
the control panel will illuminate whenever
the power key is pressed to the
on
position.
holD TeMp
Starting from the
off
position, press the
power key
on
. The SelecTIon Screen will
appear on the display. The compressor will
become energized and will begin to operate
if required by the sensors.
Press the holD TeMp key. The display will
indicate the default hold temperature
(changeable in User Settings).
To change the displayed temperature, press the
up
5
or down
6
arrow key to increase or decrease
the temperature display within the refrigeration
storage parameters of the Hold temp mode -5°F to
+40°F (-21°C to +4°C).
note
:
THE
MOdIfIEd
HOLdINg
TEMPERATURE
SET
-
POINT
IS
NOT
SAVEd
.
THE
dEfAULT
HOLd
TEMPERATURE
CAN
bE
CHANgEd
UNdER
USER
SETTINgS
.
Press the STarT/STop key to begin
operation of the Quickchiller in the Hold
temp mode.
The display will indicate:
1. The length of time the chiller is
operating in the Hold temp mode.
2. The temperature set by the operator.
3. The air temperature inside the
chiller compartment.
4. The temperature of all food probes.
When In The holD TeMp MoDe afTer a chIll
MoDe:
Press the Up
5
arrow key to display the maximum
sensor temperature achieved during the completed
chill cycle. Press the DoWn
6
arrow key to display
the minimum sensor temperature achieved during
the completed chill cycle. Press the right
4
or
left
3
arrow key to display the Probe
Done Time.
c a u t i o n
NEVER STACK PANS DIRECTLY
ON TOP OF EACH OTHER.
STACKED PANS WILL RESTRICT
AIR FLOW AND INCREASE CHILL
PROCESSING TIME.