IV. LAMP
INSTALLATION
a. Disconnect
Wobblelight
®
from power source and turn off switch.
b. Allow dome and lamp to cool completely.
c. Remove
the
Wobblelight
®
dome / cap assembly by removing the five mounting screws.
d. Screw lamp firmly but not forcibly into socket in order to avoid breakage.
e. Tighten bulb until it is secure in the socket – do not over tighten.
f. Reinstall
the
Wobblelight
®
dome / cap assembly by aligning the five mounting holes with the five mounting nuts (note the dome handle should be
aligned with the power switch).
g. Re-install the five mounting screws – do not over tighten.
V.
BROKEN ARC-TUBE: Take care in handling and disposing of metal halide lamps. If arc-tube is broken, avoid skin contact with any of the contents
and fragments. See manufacturer’s Material Safety Data Sheet for further details.
LAMP CONTAINS MERCURY: Manage in accordance with all applicable disposal laws. See
OPERATING NOTE: Metal halide lamps may require up to 60 seconds to initially start from cold condition, and another 6-8 minutes to achieve full brightness.
Metal halide lamps which are shut off and then turned back on while still hot may require 5-10 minutes to restart.
SAVE THESE INSTRUCTIONS
Specific Precautions for Halogen Units
500-watt Halogen Wobblelight
®
CAUTION!
The following instructions must be followed in order to avoid the risk of personal injury, property damage and poor lamp performance.
The halogen lamp contains an inner capsule that operates at high internal pressure and at high surface temperature and may unexpectedly shatter. The
outer glass bulb is not designed to contain hot flying particles in the unlikely event of a capsule rupture. Therefore, only operate lamp in the enclosed
Wobblelight
®
fixture with dome and cap installed and free of damage.
To avoid the possibility of fire, do not operate the halogen lamp close to materials that are combustible or affected by heat or drying.
To avoid risk of serious eye injury from the intense light, do not stare at the operating lamp.
To avoid electric shock, turn off power and let lamp cool completely before attempting replacement.
To avoid skin burns, allow lamp to cool completely before handling.
For safe and proper halogen lamp operation, operate lamp at rated voltage and wattage. Operation above rated voltage increases internal pressure and,
thus increasing the risk of rupture.