Note: Troubleshooting problems may have similar causes and solutions.

Close drain valve

Tank drai n valve is open

Check fittings with soapy water. Tighten or reseal leaking fittings.

DO NOT OVERTIGHTEN.

Fittings Leak

Make sure air inlet vents are not covered or restricted.

Restricted air intake

Decrease amount of air used.

Prolonged excessive use of air

Check air requirement of accessory. If it is higher than CFM and

pressure supplied by compressor, you need a larger compressor.

Most accessories are rated at 25% of actual CFM while running

continuously.

Compressor not large enough

Check and replace if necessary.

Hole in air hose

Immediately replace tank. DO NOT attempt to
repair.

Tank leaks

Replace compressor assembly.

Valve leaks

Replace compressor assembly.

Leaking or worn piston

Replace compressor assembly.

Blown seals

Replace regulator or internal parts.

Dirty or damaged regulator

internal parts.

If pressure drops too low, adjust regulator while accessory is used.

This is normal

Check air requirement of accessory. If it is higher than CFM and

pressure supplied by compressor, you need a larger compressor.

Most accessories are rated at 25% of actual CFM while running

continuously.

Compressor not large enough

SOLUTION

POSSIBLE CAUSE

Low pressure or not

enough air

or

Compressor does not

stop

Air leaks from regulator,

or regulator does not

regulate pressure
Regulated pressure

gauge reading drops

when air accessory is

being used

PROBLEM

WARNING

:

Replace pressure switch

Tank pressure exceeded normal

operating pressure

Replace pressure switch

Pressure switch stuck

Motor will start automatically when tank pressure drops below

kick-in pressure of pressure tank.

Tank pressure exceeds preset

pressure switch limit

Let motor cool off and overload switch will automatically reset. This

may take several minutes.

Motor overload protection has

tripped

• Replace blown fuse or resed circuit breaker. Do not use fuse or

circuit breaker with higher rating than specified for your branch

circuit.

Fuse blown or circuit breaker

tripped

• Check for proper fuse; “Fusetron” type T is acceptable.
• Check for low voltage and proper extension cord size.
• Disconnect other applications from circuit. Operate compressor

on a dedicated circuit.

Remove and clean or replace.

Check valve stuck open

Bleed line by moving pressure switch lever to OFF Position before

restarting. If bleeder valve does not open, replace bleeder valve.

Pressure bleeder valve on

pressure switch has not

unloaded head pressure

Check for proper gauge and extension cord length.

Wrong wire gauge in cord or

excessive extension cord length

Contact authorized service center.

Loose electrical connections

Contact authorized service center.

Possible defective capacitor

Have checked at service center. Do not operate compressor in the

paint spray area

Paint spray on internal motor

parts

Have checked at service center.

Possible defective motor

Pressure relief valve

opens

Motor will not run

TROUBLESHOOTING CHART