beautypg.com

Operating instructions – Powermate IV7518075 User Manual

Page 8

background image

8 - ENG

200-2909

NOTE: The pump is shipped with break-in oil which should be

changed after the first 8 hours of operation.

1. Make sure the power is connected at the power panel.

2. Check the oil level in the pump (see “Checking the Oil” in the

maintenance section).

3. Open the petcock (see

C).

Escaping air and moisture can

propel debris that may cause eye injury. Wear safety

goggles when opening petcock.

4. Turn ON the main power disconnect switch. Turn the

pressure switch to the AUTO position (see

B). The motor

should start. Allow the compressor to run for 30 minutes, to

break in the internal parts.

NOTE: After about 30 minutes, if the unit does not operate

properly, SHUT DOWN IMMEDIATELY, and contact a

qualified service center.

DO NOT return the unit to the

store where it was purchased.

5. After about 30 minutes, turn the pressure switch to the OFF

position (see

A).

6. Shut OFF the main power disconnect.

7. Close the petcock (see

D). Turn in the clockwise direction.

8. Turn ON the main power disconnect switch. Turn the

pressure switch to the AUTO position. The compressor will

start and fill the tank to the cut-out pressure and stop.

NOTE: As compressed air is used, the pressure switch will

restart the motor automatically to supply more

compressed air to the tank.

1. Check the oil level in the pump (see “Checking the Oil” in the

maintenance section).

2. Make sure the main power disconnect switch is shut OFF.

3. Close the tank petcock (see

D).

4. Turn ON the main power disconnect switch. Turn the

pressure switch to the AUTO position (see

B). The pump will

start filling the tank with air. When the air pressure in the

tank reaches the level preset at the factory, the pressure

switch will turn off the electric motor. As air is used and the

pressure level in the tank drops, the pressure switch will start

the motor and the pump will begin refilling the tank.

High temperatures are generated

by the pump. To prevent burns or other injuries, DO

NOT touch the pump or transfer tube while the pump

is running. Allow it to cool before handling or

servicing. Keep children away from the compressor

at all times.

NOTE: If the unit does not operate properly, SHUT DOWN

IMMEDIATELY, and contact a qualified service center.

In cold weather check that the air filters are clean.

NOTE: Use synthetic blend, non-detergent air compressor oil.

Open the petcock (

C) to depressurize the tank to zero PSI

before starting. If the compressor will not start, relocate it in a

warmer location.

1. Turn the pressure switch to the OFF position (see

A).

2. Shut OFF the main power disconnect switch.

3. Reduce pressure in the tank through the outlet hose. You

can also pull the tank safety valve ring (see

E) and keep it

open to relieve pressure in the tank

Escaping air and moisture can

propel debris that may cause eye injury. Wear safety

goggles when opening petcock.

4. Open the petcock (see

C) to allow moisture to drain from

the tank.

OPERATING INSTRUCTIONS

BREAK-IN OF THE PUMP

DAILY START-UP

SHUTDOWN

WARNING:

CAUTION:

CAUTION:

COLD WEATHER STARTING

CLOSE

D

E

OPEN

C