beautypg.com

Powermate IV7518075 User Manual

Page 11

background image

11 - ENG

200-2909

MAINTENANCE

SERVICE INTERVAL

Perform the following maintenance at the intervals indicated below.

Daily

or after

each use

Every 200

operating

hours

Every 250

operating

hours

After first 8 hours

and then every 500

operating hours

Inspect air filters (clean or replace as necessary)

Check pump oil level

Change pump oil (Use synthetic blend, nondetergent air compressor oil.)

Operate the tank safety valve

Check belt tension

Drain tank

Check and tighten all bolts (do not over tighten)

7. Apply thread sealant to the check valve

threads and reinstall into the tank by

turning clockwise. Make sure it is the

same orientation as when it was removed.

8. Replace the bleeder tube and tighten

compression nut.

9. Replace the transfer tube and tighten

compression nuts.

10. Perform the “Break-in of the pump”

procedure in the Operating Instructions to

make sure there are no leaks and the

check valve is working properly.

A dirty air filter

will reduce the

compressor’s

performance and life.

To avoid any internal

contamination of the

pump, the filters should

be cleaned frequently,

and replaced on a

regular basis. Felt filters

should be cleaned in

warm, soapy water,

rinsed, and allowed

to air dry before

reinstallation. Paper filters should be replaced when dirty. Do

not allow the filters to become filled with dirt or paint. If the filter

becomes filled with paint, it should be replaced. Direct exposure

to dirty conditions or painting areas will void your warranty.

Pull the tank safety valve daily to ensure that it is operating

properly and to clear the valve of any possible obstructions.

Check that all connections are tight. A small leak in any of

the hoses, transfer tubes, or pipe connections will substantially

reduce the performance of your air compressor. If you suspect

a leak, spray a small amount of soapy water around the area

of the suspected leak with a spray bottle. If bubbles appear,

repair or replace the faulty component. Do not over tighten any

connections.

Before storing the compressor for a prolonged period, use

an air blow gun to clean all dust and debris from the compressor.

Disconnect the power cord and coil it up. Pull the tank safety

valve to release all pressure from the tank. Drain all moisture from

the tank. Clean the filter elements and filter housings; replace

the elements if necessary. Drain the oil from the pump crankcase

and replace it with new oil. Cover the entire unit to protect it from

moisture and dust.

CLEANING THE AIR FILTERS

CHECKING THE RELIEF VALVE

TESTING FOR LEAKS

STORAGE

A

B

C

A = Wing nut(s)

B = Metal cover(s)

C = Filter element(s)