SELECT SUITABLE LOCATION
Locate the welder in a dry location where there is free
circulation of clean air into the louvers in the back and
out the front of the unit. A location that minimizes the
amount of smoke and dirt drawn into the rear louvers
reduces the chance of dirt accumulation that can
block air passages and cause overheating.
STACKING
WIRE FEEDER WELDER(180 MODEL) cannot be
stacked.
TILTING
Each machine must be placed on a secure, level sur-
face, directly or on recommended cart. The machine
may topple over if this procedure is not followed.
Read entire installation section before starting
installation.
SAFETY PRECAUTIONS
---------------------------------------------------
ELECTRIC SHOCK can kill.
• Only qualified personnel should perform
this installation.
• Only personnel that have read and under-
stood the POWER MIG Operating Manual
should install and operate this equipment.
• Machine must be plugged into a receptacle
which is grounded per any national, local
or other applicable electrical codes.
• The POWER MIG power switch is to be in
the OFF (“O”) position when installing
work cable and gun and when connecting
power cord to input power.
WARNING
A-1
A-1
INSTALLATION
WIRE FEEDER WELDER (180 MODEL)
TECHNICAL SPECIFICATIONS 180 Amp units (K2481-1, K2515-1, K2659-1, K2689-1, K2698-1)
INPUT – SINGLE PHASE ONLY
RATED OUTPUT
OUTPUT
Standard Voltage/Frequency
Input Current
230 V 60 Hz
20 Amps @ rated output
208 V 60 Hz
20 Amps @ rated output
Voltage/Duty Cycle
Current
Voltage at Rated Amperes
230 V 30%
130 Amps
20
208 V 30%
130 Amps
17
Welding Current Range
Open Circuit Voltage
Wire Speed Range
30-180 Amps
34 V
50 - 500 in/min.
(1.3 - 12.7 m/min.)
Input Voltage/Frequency Fuse or Breaker Size
1
Input Amps Power Cord
230 V 60 Hz
40 Amp Super Lag
20 50 Amp, 250 V,
Three Prong Plug
(NEMA Type 6-50P)
RECOMMENDED INPUT CABLE AND FUSE SIZES
Height
Width
Depth
Weight
13.7 in
10.15 in
17.9 in
64 Ibs
347 mm
258 mm
454 mm
29 kg
PHYSICAL DIMENSIONS
1
If connected to a circuit protected by fuses use Time Delay Fuse marked “D”.
OPERA
T
ORʼS MANUAL