beautypg.com

Diagramas, Idealarc dc-600 – Lincoln Electric IM306 IDEALARC DC-600 User Manual

Page 48

background image

IDEALARC DC-600

F-3

DIAGRAMAS

F-3

211

212

SW1

START

STOP

255

X1

X2

T2

H1

H2

H3

VM

AM

+

+

-

-

210

210

SW2

222

222

21

2

31

32A

32

21

42

31

32

T.S.2

N.C.

226

238

236

R1

237

75

80

OUTPUT

CONTROL

229

215

232

224

81

77

76

76

75

77

80

81

T.S.3

80

280

81

229

215

210

81

215

220

280

1

1

2

2

3

3

4

4

5

5

6

6

7

8

9

1

2

80

226

224

232

75

222

235

256

255

231

238

233

J1

J2

J3

CONTROL

P.C. BOARD

203

1

1

2

2

33

4

4

5

5

6

6

7

8

9

J4

J5

FIRING

CIRCUIT

P.C. BOARD

TO T1 AUX. WINDING

2

4

210

215

220

215

215

215

+

-

WORK

ELECTRODE

LEADS 210 & 215 ARE

TWISTED TOGETHER

TO STICK ELECTRODE HOLDER OR

AIR-CARBON ARC TORCH

TO "WORK" USED WITH STICK

OR AIR-CARBON ARC

STICK WORK LEAD NOT

USED WHEN JUMPER IS

USED.

OPTIONAL USER SUPPLIED JUMPER FOR

THOSE SITUATIONS WHERE IT IS NOT

CABLES FOR STICK AND SEMI-AUTOMATIC

WELDING.

N.D.

N.E.

N.D., N.F.

OPTIONAL

MULTI-PROCESS

SWITCH

210

210

210

215

OUTPUT SHUNT

(50MV @800 AMPS}

220

215215

OUTPUT

CHOKE

C7

222

OUTPUT

N.D.

(+)

(-)

215

210

222

R2

214

A

B

7

4

8

5

9

6

31

215

216

32A

31

FAN

MOTOR

215

272

273

SEC. LEAD

THERMOSTAT

256

PRIMARY

THERMOSTAT

256

PILOT

LIGHT

233

235

255

B

5

7

A

271

271

R

S

S

F

F

32A

207

208

18

3

6

15

12

S

F

205

206

17

2

5

14

11

AUX. 1

S

F

203

204

F

31

S

AUX.2

16

1

PRI.

4

13

PRI.

10

SEC.

SEC.

T1

THERE IS NO

10, 11 & 12

CONNECTION

ON 380 OR

TRIPLE VOLTAGE

MACHINES.

4

TO INPUT

PANEL

SCR

SCR

SCR

SCR

SCR

SCR

1

2

3

4

5

6

OUTPUT

SNUBBER

G6

G4

G2

P.C. BOARD

OUTPUT RECTIFIER

ASSEMBLY

GATE

LEADS TO

CIRCUIT

FIRING

BOARD

P.C.

SCR

LEGEND

C7 .05 +.05 MFD

F1 8 AMP SLOW BLOW FUSE

R1 10K POT

T1 MAIN POWER TRANSFORMER

R2 30 , 100W

T2 CONTROL TRANSFORMER

2CR FAULT PROTECTION RELAY

1CR INPUT CONTACTOR

4CR OUTPUT PILOT RELAY

3CR CURRENT ACTIVATED REED SWITCH

SW1 INPUT POWER

SW2 ELECTRODE POLARITY

SW3 OUTPUT CONTROL

SW4 WELDING MODE (SHOWN IN STICK POSITION)

NOTES:

N.B. FOR STICK WELDING OR AIR CARBON ARC

WITHOUT A MULTI-PROCESS SWITCH INSTALLED,

DISCONNECT ALL ELECTRODE, WORK, AND

CONTROL LEADS TO ANY WIRE FEEDERS.

JUMPER 2 TO 4. OUTPUT TERMINALS WILL

NOW BE ENERGIZED. PLACE MODE SWITCH

IN VV FOR STICK AND CV (I) FOR AIR

CARBON ARC. SEE OPERATING MANUAL

FOR FURTHER INSTRUCTIONS.

N.C. CENTER TERMINAL OF FUSE HOLDER.

N.D. WELDING CABLE MUST BE OF THE PROPER

CAPACITY FOR THE CURRENT AND DUTY CYCLE

OF IMMEDIATE AND FUTURE APPLICATIONS.

"POSITIVE". TO CHANGE THE POLARITY, TURN

THE DC-600 OFF, AND REVERSE THE LEADS AT

THE MULTI-PROCESS SWITCH.

CONNECTION DIAGRAM, CONNECT ELECTRODE

AND WORK LEADS TO THESE TERMINALS

INSTEAD OF THE POWER SOURCE

OUTPUT TERMINALS.

THESE NOTES APPLY ONLY TO DC-600 WITH A

MULTI-PROCESS SWITCH INSTALLED.

SNUBBERS

+

-

G1

G3

G5

F1

N.E. THIS DIAGRAM SHOWS THE "STICK" POLARITY

N.F. USING A WIRE FEEDER, K-317 OR K-318

215

GATE LEADS TO

FIRING CIRCUIT

NECESSARY TO HAVE SEPARATE GROUND

A

AA

A

A

A

CC

C

C

C

C

TO GROUND PER

NATIONAL

H1

X1

TO

SUPPLY

LINES

L3

L2

L1

272

TO PRIMARY COILS

CODE

ELECTRICAL

1CR

RECONNECT

PANEL

H2

FOR LOW VOLTAGE)

(SHOWN CONNECTED

3

5

1

N.A.

1

3CR

4CR

2CR

SW3

SW4

J4

J4

10

7

8

9

10

11

12

13

14

J7

1

2

3

4

5

6

7

8

10

11

12

1

2

3

4

J6

A

B

B’

C

C’

A’

G3

G6

G1

G4

G5

G2

216

206

204

215

215

205

208

207

231

X

Y

Z

RECTIFIER

ASSEMBLY

TO OUTPUT

ELECTRICAL SYMBOLS PER E1537

J3

J1

J7

CONNECTOR CAVITY NUMBERING SEQUENCE

(VIEWED FROM COMPONENT SIDE OF BOARD)

J6

J4

J2

J5

271

H3

H4

9

6

4

7

8

2

230/460/575V.

1

2

3

15,14,13

18,17,16

N.A.

N.A.

N.A.

N.A. TAPE UP SEPARATELY TO PROVIDE AT LEAST

600V. INSULATION.

10-9-98F

L10577

ALL LEADS

EXCEPT

10, 11, 12

78

9

0

1

2

4

5CR POWER INTERLOCK RELAY

5CR

272

271

N.G.

2CR

271

4

7

A

B

255

255

N.G. 2CR IS SHOWN AS SPST RELAY. IF 2CR IS A 3PDT, LEADS 255

271

CONNECT TO TERMINAL 4 INSTEAD OF TERMINAL 5.

Este diagrama es s

ó

lo referencia. No es preciso para todas las m

á

quinas que cubre este manual. El diagrama espec

ífico para un c

ó

digo particular se incluyen dentro de la m

á

quina en

uno de los paneles de la cubierta. Si el diagrama es ilegible, escriba al Departamento de Servicio para obtener un reemplazo.

Proporcione el n

ú

mero de c

ó

digo de equipo.

DIA

GRAMA DE CABLEADO (230/460/575)