SELECT SUITABLE LOCATION
Locate the POWER MIG® 180 DUAL in a dry location
where there is free circulation of clean air into the lou-
vers in the back and out the front of the unit. A loca-
tion that minimizes the amount of smoke and dirt
drawn into the rear louvers reduces the chance of dirt
accumulation that can block air passages and cause
overheating.
STACKING
POWER MIG® 180 DUAL cannot be stacked.
TILTING
Each machine must be placed on a secure, level sur-
face, directly or on recommended cart. The machine
may topple over if this procedure is not followed.
Read entire installation section before starting
installation.
SAFETY PRECAUTIONS
---------------------------------------------------
ELECTRIC SHOCK can kill.
• Only qualified personnel should perform
this installation.
• Only personnel that have read and under-
stood the POWER MIG® 180 DUAL
Operating Manual should install and oper-
ate this equipment.
• Machine must be plugged into a receptacle
which is grounded per any national, local
or other applicable electrical codes.
• The POWER MIG® 180 DUAL power switch
is to be in the OFF (“O”) position when
installing work cable and gun and when
connecting power cord to input power.
WARNING
A-1
A-1
INSTALLATION
POWER MIG® 180 DUAL
TECHNICAL SPECIFICATIONS 180 Amp unit (K3018-1)
INPUT – SINGLE PHASE ONLY
RATED OUTPUT
OUTPUT
Standard Voltage/Frequency
Input Current
230 V 60 Hz
208 V 60 Hz
20 Amps @ rated output
120 V 60 Hz
Voltage/Duty Cycle
Current
Voltage at Rated Amperes
230 V 30%
130 Amps
20
208 V 30%
130 Amps
17.6
120 V 20%
90 Amps
19.5
Welding Current Range
Open Circuit Voltage
Wire Speed Range
(208V / 230V) 30-180 Amps
34 V
50 - 500 in/min.
(120V) 30-140 Amps
33 V
(1.3 - 12.7 m/min.)
Input Voltage/Frequency Fuse or Breaker Size
1
Input Amps Power Cord
230V / 208V 60 Hz
40 Amp 20 Lincoln Electric
Part Number:
M22590
120V 60 Hz
20 Amp
2
20 Lincoln Electric
Part Number:
M22589
RECOMMENDED INPUT CABLE AND FUSE SIZES
Height
Width
Depth
Weight
14.08 in
10.37 in
18.78 in
66 Ibs
357.6 mm
263.4 mm
477.6 mm
30 kg
PHYSICAL DIMENSIONS
1
If connected to a circuit protected by fuses use Time Delay Fuse marked “D”.
2
Requirements for maximum output: In order to utilize the maximum output capability of the machine, a branch circuit
capable of 30 amps @ 120 volts, 60Hz is required.