beautypg.com

Troubleshooting, Caution – Lincoln Electric IM10076 LN-25 PRO User Manual

Page 37

background image

E-4

TROubLEShOOTING

E-4

LN-25™ PRO

Observe all Safety Guidelines detailed throughout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

CAuTION

PRObLEMS

(SYMPTOMS)

POSSIbLE

CAuSE

RECOMMENDED

COuRSE OF ACTION

Variable or "hunting" arc.

Poor arc starts with sticking or
"blast-offs", weld porosity, narrow
and ropy looking bead.

1. Wrong size, worn and/or melted

contact tip.

2. Worn work cable or poor work

connection.

3. Wrong polarity.

4. The gas nozzle is extended

beyond the contact tip or the wire
stickout is too long.

5. Poor gas shielding on processes

requiring gas.

1. Improper procedures or tech-

niques.

1. Replace the contact tip.

2. Verify all work and electrode con-

nections are tight and that the
cables are in good condition.
Clean/replace as necessary.

3. Adjust polarity to the recommend-

ed procedure.

4. Adjust the gas nozzle and shorten

the stickout to 3/8 to 1/2 inches.

5. Check gas flow and mixture.

Remove or block sources of
drafts.

1. See "Gas Metal Arc Welding

Guide" (GS-100).

Output Problems