A-1
INSTALLATION
BIG RED™ 600
A-1
TECHNICAL SPECIFICATIONS - BIG RED™ 600
(K2811-1)
Make/Model
Description
Speed (RPM)
Displacement
Starting
Capacities
System
Deutz
3 cylinder
Idle 1890
173 cu. in
12VDC battery
Fuel
F3L 912
44HP (33 kw)
(2.83L)
& Starter
(20 US gal)
Diesel Engine
@ 1800 RPM
Full Load 1800
75.7L
Bore x Stroke
Oil:
3.94” x 4.72”
9.5 QTS.
(100mm x 120mm)
9.0L
INPUT - DIESEL ENGINE
1. Output rating in watts is equivalent to volt-amperes at unity power factor. Output voltage is within ± 10% at all loads up to
rated capacity. When welding, available auxiliary power will be reduced.
2. To Top of enclosure, add 8.28”(210.1mm) to top of exhaust pipe.
RATED OUTPUT @ 104° F (40° C) - WELDER
HEIGHT WIDTH
DEPTH
WEIGHT
36.87
(2)
in. 28.28 in 65.1 in.
916.5 mm
718.3 mm
1653.5 mm
Welding Process
DC Constant Current
TIG
OUTLETS
1
1
1
Output Range
Amps
65A TO 600A
65A TO 250A
Max. Weld OCV
Voltage @ 1800RPM
90 Volts
75 Volts
Welding Output
Current/Voltage/Duty Cycle
500A / 40V / 100%
550A / 34V / 60%
600A / 30V / 40%
250A / 20V / 100%
VOLTS
120
120
240
AMPS
20
15
15
POWER
2400 Watts
1800 Watts
3600 Watts
Auxiliary Power
1
Single Phase 60 Hz AC
PHYSICAL DIMENSIONS
RATED OUTPUT @ 104° F (40° C)
.
- GENERATOR
1657 lbs. (752 kg.)
RECEPTACLES AUXILIARY POWER CIRCUIT BREAKER OTHER CIRCUIT BREAKERS
1 - 120VAC Duplex NEMA(5-20R) GFCI protected 1 - 20 AMP for 120 VAC Duplex (NEMA)
1 - 120VAC European (IEC-309)-GFCI protected 1 - 15 AMP for 120 VAC European (IEC-309)
20AMP for Battery Charging Circuit
1 - 240VAC European (IEC-309) 1 - 15 AMP for 240 VAC European (IEC-309)
RECEPTACLES AND CIRCUIT BREAKERS