B-8

OPERATION

B-8

BIG RED™ 600

AUXILIARY POWER:

The auxiliary power is independent of the welding
power and thus not effected by the weld control set-
tings.

Simultaneous Welding and Auxiliary Power Loads

The auxiliary power ratings are with no welding load.
Simultaneous welding and power loads are speci-
fied in the following Table B.4.

Weld

Amps

0

100
200
300
400
500
600

1 PHASE (120V)
WATTS AMPS

2400 20
2400 20
2400 20
2400 20
1200 10

0 0
0 0

1 PHASE (240V)
WATTS AMPS

3600 15
3600 15
3600 15
2400 10
1200 5

0 0
0 0

BIG RED™ 600 Simultaneous Welding and Power Loads

PLUS

OR

TABLE B.4

BIG RED™ 600 Extension Cord Length Recommendations

(Use the shortest length extension cord possible sized per the following table.)

Current

(Amps)

15

20
15

Voltage

Volts

120
120
240

Load

(Watts)

1800
2400
3600

30

60

(9)

(18)

40
30
75

(12)

(9)

(23)

75
50

150

(23)
(15)
(46)

125

88

225

(38)
(27)
(69)

175
138
350

(53)
(42)

(107)

300
225
600

(91)
(69)

(183)

Maximum Allowable Cord Length in ft. (m) for Conductor Size

Conductor size is based on maximum 2.0% voltage drop.

14 AWG

12 AWG

10 AWG

8 AWG

6 AWG

4 AWG

TABLE B.5