Step 5: backplane installation – IEI Integration RACK-2100G User Manual
Page 6

RACK-2100G QIG
IEI Technology Corp. Page 6
Step 6:
Secure the PSU to the chassis with two additional
retention screws.
Figure 13: Secure the PSU to the Chassis
Step 7:
Insert the power modules into the PSU and lock them in
place by tightening the thumbscrews.
Step 0:
Figure 14: Insert the PSU Modules
STEP 5: BACKPLANE INSTALLATION
The IEI backplanes listed below are compatible with the
RACK-2100G chassis.
Model No.
SBC Type
PCI
PSU
Connector
PE-6SD PICMG
1.3
0
ATX
PE-6SD2 PICMG
1.3
1
ATX
Table 3: Compatible Backplane Modules
The backplane is installed into a backplane bracket. To install the
backplane follow the instructions below.
Step 1:
Remove the backplane by removing the six retention
screws that secure the backplane bracket. Remove two
retention screws from the base and four from the rear of
the chassis.
Figure 15: Two Backplane Bracket Retention Screws on the
Base of the Chassis
Figure 16: Four Backplane Bracket Retention Screws at the
Rear of the Chassis
Step 2:
Mount the backplane onto the backplane bracket. Make
sure the backplane is properly aligned with the
preformed holes in the bracket.
Step 3:
Secure the backplane to the backplane bracket with
eight retention screws.
Step 0:
Figure 17: Insert Eight Retention Screws