Errata, Availability – Allied Telesis SB244-03 User Manual
Page 8
8
Patch Release Note
Patch SB244-03 for Software Release 2.4.4
C613-10349-00 REV C
Packets with a RIP source address and next hop address that are not on the
same subnet as the interface will now be processed. If the received next hop
is not on the same subnet, it is treated as 0.0.0.0.
On GBICs, the link was forced up when the transmit fibre was removed.
Once up, the link could not be taken down again by removing the transmit
fibre. This issue has been resolved.
IGMP messages sometimes caused a fatal error. This issue has been
resolved.
Multicast downstream groups are now added and deleted correctly.
Errata
AT-9800 Series Switches do not have Ethernet interfaces (for example, eth0).
Previously released documentation incorrectly states that these interface types
are valid. AT-9800 switch ports are Ethernet ports, and these are referenced in
commands with the PORT parameter.
IPSec and ISAKMP are not available on the 2.4.4 release for SwitchBlade 4000
Series Switches and AT-9800 Series Switches.
Availability
Patches can be downloaded from the Software Updates area of the Allied
Telesyn web site at
. A
licence or password is not required to use a patch.
PCR: 02415
Module: IPG
Network affecting: No
PCR: 02420
Module: SWI
Network affecting: No
PCR: 02423
Module: SWI
Network affecting: No
PCR: 02425
Module: IPG
Network affecting: No