beautypg.com

Allied Telesis SB244-03 User Manual

Page 5

background image

Patch SB244-03 For SwitchBlade 4000 Series Switches and AT-9800 Series Switches

5

Patch SB244-03 for Software Release 2.4.4
C613-10349-00 REV C

Sometimes a port reported an interface as being down, but the port counters
kept incrementing. This issue has been resolved.

The CREATE TRIGGER MODULE=SWITCH command now recognises
ports in x.y notation when specifying the PORT parameter.

A fatal error occurred on SwitchBlade 4000 Series Switches when booting
from a script that added ports to a trunk group that was hot swapped out.
This issue has been resolved.

Support for multi-homed interfaces has been added.

The board descriptions have changed for some instances of AT-9800 Series
Switches.

When a Telnet session was closed, SWITCH debug was not disabled if it had
been enabled for the Telnet session. This issue has been resolved.

After an ASYN port test, the port is now reset to its pre-test state if the test
was started by a user connected to the same ASYN port.

The Built-in Self Test failed on SwitchBlade chassis. This issue has been
resolved.

The configuration was not restored correctly after a line card was hot
swapped out. This issue has been resolved.

A string compare error was occurring in the conditional statement of the
script. This issue has been resolved.

PCR: 02460

Module: SWI

Network affecting: No

PCR: 02461

Module: SWI

Network affecting: No

PCR: 02462

Module: SWI

Network affecting: No

PCR: 02463

Module: DVMRP, IPG

Network affecting: No

PCR: 02467

Module: CORE

Network affecting: No

PCR: 02468

Module: SWI

Network affecting: No

PCR: 02469

Module: TM

Network affecting: No

PCR: 02470

Module: SWI

Network affecting: No

PCR: 02476

Module: VRRP, CORE

Network affecting: No

PCR: 02478

Module: SCRIPT

Network affecting: No