beautypg.com

Hood service procedures – XLT XD-9007A (ELEC Oven Version – B1, AVI Hood Version – B) User Manual

Page 20

background image

20

Technical Support US: 888-443-2751

Technical Support INTL: 316-943-2751

HOOD SERVICE PROCEDURES

Complete VFD manual available at

www.xltovens.com

Hitachi X200 Restoring Factory Defaults

Access program parameters by pressing the key one time and using the up and down ar-
row keys to navigate to the appropriate parameter press the key again to make adjust-
ments to that parameter by using the up and down arrows. To store the new settings press the
button one time.

B031 = 01
B084 = 01

After pressing the key Press and hold the down arrow key and

Reset> key all at the same time. Release the keys all at once and the country code
should appear in the display (USA). Hitachi’s factory settings are now restored.

A001 = 01
A003 – USA = 60 Hz. World = 50 Hz.
A082 = Supply voltage at location 200, 215, or 230 choose appropriate voltage.
A093 = 3000
A094 = 01
A096 = 10
B002 = 25
C001 = 02
C002 = 03
C003 = 04
C004 = 05
C014 = 00
F001 = See Figure 1
H004 = 4
B031 = 03

Put controller into monitor mode by pressing the and holding until d001 appears on the

display release and then press the one time. The display should show 0.0.

Put the controller in Run mode by pressing the key one time. The Run indicator light lo-

cated next to the speed control knob should illuminate.

Test run the motor by turning on one of the oven/hood switches located on the face of the hood.