Oven service procedures, Temperature control programming procedure – XLT XD-9007A (ELEC Oven Version – B1, AVI Hood Version – B) User Manual
Page 19
![background image](/manuals/355632/19/background.png)
19
Technical Support US: 888-443-2751
Technical Support INTL: 316-943-2751
Temperature Control Programming Procedure
OVEN SERVICE PROCEDURES
Configuration Key Functions
The new setting of the selected parameter is stored
and the display advances to the next parameter. This
is required between each parameter.
=
Increases the setting of the selected parameter.
=
Decrease the setting of the selected parameter.
1. Open V101 switch for Basic Configuration (Figure 1)
Turn main switch to the off position
Remove instrument from its case
Open Switch V101
Re-insert the instrument back in its case.
Turn main switch to the on position
2. Basic Configurations
Using the configuration keys scroll thru parameter codes
changing them to match (Figure 2)
After P12 _._._._. Will appear
3. Close V101 switch after Basic Configuration (Figure 1)
Remove instrument from its case
Close Switch V101
Re-insert the instrument back in its case.
Error 400 will appear press and hold the and to clear
000 will appear
4. Advanced Configurations Procedure
Using the configuration keys scroll thru parameter codes
Changing them to match (Figure 3)
On the first pass thru change nnn to 311 to unlock the
advanced configuration
Scroll thru the parameter codes again and change the nnn to 5
this locks the advanced configuration
Scroll thru the parameter codes again and verify nnn is ON
SP
260˚C/500˚F
nnn
311/5
AL
315˚C/600˚F
HSA
.1
Pb
4.0
ti
5.0
td
.00
1P
30
C
2
rL
204˚C/400˚F
rH
310˚C/590˚F
OLH
100
tOL
InF
Read the entire instruction before programming.
P1
2˚C/10˚F
P2
0
P3
315˚C/600˚F
P4
r
P5
1
P6
H.A.
P7
d
P8
OFF
P9
0
P10
100
P11
311
P12
7
Figure 2