Chapter 4 MXT 300 Display

MXT 300 Display Indication

The MXT 300 display and reference label below the

display provide a wealth of information about the

metal target. It is important, however, to understand

the display information should only be consulted

after a solid repeatable audio tone "beep" has been

located.

The MODE selection changes the type and content

of the information shown by the display better suit-

ing the MXT 300 to the application, Coin & Jew-

elry, Relic, or Prospecting.

In all MODEs, the display will momentarily show

a software version and battery voltage upon fi rst

turning the GAIN "on". The MXT 300 operates on

a twelve volt battery system which with new quality

batteries will indicate 12 + volts. During search-

ing "LoBat" will start appearing on the display at

8 volts and anything 8 volts and below are suspect

for replacement. If using rechargeable batteries 8

volts is surely the end of their performance. If you

are using quality alkaline batteries you do have a

reserve after 8 volts. The MXT 300 utilizes a low

voltage regulator. Quality alkaline batteries will

provide normal performance (in a pinch) well into

the LoBat indication.

Coin & Jewelry MODE;

The Coin & Jewelry MODE provides 5 different

signifi cant indications on the display.

1. VDI = number - The VDI (Visual Discrimi-

nation Indication) is a reference number dictated

mostly by the metals targets exact alloy, size,

and shape. The reference label below the display

provides a comparison of known targets and their

common VDI numbers. Like targets produce like

VDI numbers. Similar targets produce similar VDI

numbers. And different targets produce different

VDI numbers. Different metal targets, however,

may share the same VDI numbers based on their

electrical characteristics. VDI numbers from -95 to

+94 are available and cover the entire range of al-

loys and sizes.

VDI number on display

VDI number range on reference label

Mode toggle switch
forward for Coin and
Jewelry