Cbc-160-2n, Cbc-160-1n, Connection diagrams – Warner Electric CBC-160-2N User Manual
Page 4

4
Warner Electric • 800-825-9050
P-239-36 • 819-0450
WYE Connected Motor
T7 T8 T9
T1 T2 T3
T4 T5 T6
480 VAC
Red +
Red/white
•
•
CBC-160-2N
Black/red
White
240 VAC
90 VDC
BRAKE
(Motor Terminals)
+
-
0
100
50
T7 T8 T9
T1 T2 T3
T4 T5 T6
230 VAC
Red +
Red/white
•
•
CBC-160-2N
Black/red
White
230 VAC
90 VDC
BRAKE
(Motor Terminals)
+
-
0
100
50
3 4
1 2
8 5
120 VAC Motor
Red +
Red/white
•
•
CBC-160-1N
Black/red
White
120 VAC
90 VDC
BRAKE
+
-
0
100
50
2 5
1 4
3 8
230 VAC Motor
Red +
Red/white
•
•
CBC-160-1N
Black/red
White
120 VAC
90 VDC
BRAKE
+
-
NOTE: If motor direction needs to be reversed, wires 5 & 8
are reversed. Corrections to CBC-160-1N do not change.
0
100
50
Figure 2
Figure 3
Connection Diagrams
Figure 4
This manual is related to the following products: