Introduction, About qualiphy, About qphy-pcie – Teledyne LeCroy QPHY-PCIe User Manual
Page 5: Required hardware
![background image](/manuals/353680/5/background.png)
QPHY-PCIE Operator’s Manual
Introduction
About QualiPHY
QualiPHY is a highly automated compliance test software meant to help you develop and
validate the PHY (physical-electrical) layer of a device, in accordance with the official
documents published by the applicable standards organizations and special interest groups
(SIGs). You can additionally set custom variables and limits to test compliance to internal
standards.
QualiPHY is composed of a “framework” application that enables the configuration and control
of separate tests for each standard through a common user interface. Features include:
• Multiple Data Source Capability: Connect to your X-Stream oscilloscope via LAN or
other interfaces.
• User-Defined Test Limits: Parameter interconnect losses can be factored into the
parametric results.
• Flexible Test Results Reporting that includes XML Test Record Generation.
Understand a device performance distribution, or obtain process related information from
the devices under test.
About QPHY-PCIE
QPHY-PCIE is an automated test package performing all the normative, real-time oscilloscope
tests for sources in accordance with PCI Express Card Electromechanical Specification, Rev.
3.0.
The software can be run on any Teledyne LeCroy real-time oscilloscope with at least 6 GHz
bandwidth for 2.5 GT/s testing and 13 GHz for 5.0 GT/s testing.
Required Hardware
• Real-time Teledyne LeCroy oscilloscope with the QualiPHY software and an activated
QPHY-PCIE component
• 2 pair standard SMA-SMA cables for Gen 1 fixtures
• 1 pair standard SMA-SMP cables for Gen 2 fixtures
• PCIE base board (CBB) for testing system boards
• PCIe load board (CLB) for testing add-in cards
For the most complete and up-to-date list, see the PCI SIG website:
www.pcisig.com/specifications/pciexpress/compliance
922543 Rev Error! Reference source not found.