Teledyne LeCroy CPCI-H110 User Manual
Page 5

5
JUMPERS TABLE
Description
Jumper
Utilization
External power input
J5
Inputs from external power supply
Current measurement
J3
Outputs to DVM
-12V isolation from the system
JP4
On = voltage from system, Off = from Ext. supply
+12V isolation from the system
JP6
On = voltage from system, Off = from Ext. supply
+5V isolation from the system
JP5
On = voltage from system, Off = from Ext. supply
+VIO connection to the system through the extender
JP10
On = VIO from the system, Off = from UUT plane
If this jumper is removed the UUT VIO signals must
be connected to the main voltage plane.
+3.3V source
JP7
On-board = Between 1 & 2, from system = 2 & 3
Square pad on the 3 pin jumper is pin 1.
+5V current limit selection
JP2
On = 2A, Off = 10A
VRG
JP30 On = voltage from system
-SELVBATRTN
JP31
On = voltage from system
-SELVBAT
JP32
On = voltage from system
-VBAT
JP33
On = voltage from system
VBATRTN
JP34
On = voltage from system
VRGRTN
JP35
On = voltage from system
LEDs
There are two sets of LED on the board, green and red. Each LED has a label which Voltage it represents. The green
LED, when illuminated, indicates presence of the corresponding voltage. The red LED, when illuminated, represents a
short on the corresponding voltage. Please note that the green LEDs do not necessarily indicate if the voltage is at the
expected level or not.
Voltage
Green LED
Red LED
+3.3V
D5
D6
+5V
D15
D7
+12V
D4
D11
-12V
D3
D2
+VIO
D9
N/A