beautypg.com

Teledyne LeCroy CPCI-H110 User Manual

Page 5

background image

5

JUMPERS TABLE

Description

Jumper

Utilization

External power input

J5

Inputs from external power supply

Current measurement

J3

Outputs to DVM

-12V isolation from the system

JP4

On = voltage from system, Off = from Ext. supply

+12V isolation from the system

JP6

On = voltage from system, Off = from Ext. supply

+5V isolation from the system

JP5

On = voltage from system, Off = from Ext. supply

+VIO connection to the system through the extender

JP10

On = VIO from the system, Off = from UUT plane

If this jumper is removed the UUT VIO signals must
be connected to the main voltage plane.

+3.3V source

JP7

On-board = Between 1 & 2, from system = 2 & 3

Square pad on the 3 pin jumper is pin 1.

+5V current limit selection

JP2

On = 2A, Off = 10A

VRG

JP30 On = voltage from system

-SELVBATRTN

JP31

On = voltage from system

-SELVBAT

JP32

On = voltage from system

-VBAT

JP33

On = voltage from system

VBATRTN

JP34

On = voltage from system

VRGRTN

JP35

On = voltage from system

LEDs

There are two sets of LED on the board, green and red. Each LED has a label which Voltage it represents. The green
LED, when illuminated, indicates presence of the corresponding voltage. The red LED, when illuminated, represents a
short on the corresponding voltage. Please note that the green LEDs do not necessarily indicate if the voltage is at the
expected level or not.

Voltage

Green LED

Red LED

+3.3V

D5

D6

+5V

D15

D7

+12V

D4

D11

-12V

D3

D2

+VIO

D9

N/A