BEFORE PLACING DOOR OPERATOR IN REGULAR SERVICE, MAKE SURE THAT:

1. THE FRONT AND REAR MOUNTS FOR THE OPENER ARE SOUND AND SECURE AND THE

RAIL IS POSITIONED CORRECTLY ABOVE THE HIGH ARC OF THE DOOR, AND THAT

THE OPENER IS POSITIONED OVER THE DOOR ACTION CENTERLINE.

2. FOR SECTIONAL DOORS AND ONE-PIECE DOORS WITH TRACKS, THE POSITION OF

THE DOOR ARM, WITH THE DOOR CLOSED, IS SUCH THAT ITS CONNECTING POINT

ON THE TROLLEY IS 5" TO 8" BEHIND ITS CONNECTING POINT ON THE DOOR

BRACKET. THE DOOR ARM SHOULD NEVER BE PERFECTLY VERTICAL WHEN THE

DOOR IS IN THE CLOSED POSITION.
FOR ONE-PIECE DOORS WITHOUT TRACKS, THE POSITION OF THE DOOR ARM, WITH

THE DOOR CLOSED, IS SUCH THAT ITS CONNECTING POINT ON THE TROLLEY IS 20"

TO 22" BEHIND ITS CONNECTING POINT ON THE DOOR BRACKET. THE STRAIGHT

PORTION OF THE DOOR ARM SHOULD BE AT AN ANGLE OF 15-20° WITH RESPECT TO

THE FLOOR WHEN THE DOOR IS CLOSED.

3. THE EMERGENCY RELEASE HANDLE AND CORD ARE SECURE TO THE EMERGENCY

RELEASE LEVER. THE HANDLE IS LOCATED 6 FT ABOVE FLOOR LEVEL AND

REQUIRES NO MORE THAN 50 LBS. PULL TO ACTUATE. THE TROLLEY AND RELEASE

MECHANISM ARE PROPERLY LUBRICATED.

4. THE STANDARD WALL PUSH BUTTON OR THE SUPER STATION (DELUXE WALL

PUSHBUTTON STATION) IS IN SUCH A POSITION AND OF SUCH A HEIGHT THAT IT CAN

ONLY BE ACTUATED BY AN ADULT OF AVERAGE HEIGHT. THE CAUTION LABEL IS

PROMINENTLY DISPLAYED NEXT TO THE PUSH BUTTON OR WALL STATION.

5. ALL WIRING IS CORRECT TO CODES OR BETTER. THERE IS GROUND CONTINUITY IN

THE SUPPLY. THE GROUND PRONG ON THE POWER CORD IS INTACT.

6. ALL ROPES HAVE BEEN REMOVED FROM THE DOOR. THE DOOR MOVES FREELY

WITHOUT BINDING WHEN RAISED OR LOWERED MANUALLY. THE DOOR IS

CORRECTLY BALANCED AND LUBRICATED. ALL DOOR HARDWARE IS SECURE AND

SOUND. THE SENSITIVITY HAS BEEN ADJUSTED TO MINIMUM FORCE FOR THE

APPLICATION. THE APPROPRIATE WARNING STICKER HAS BEEN AFFIXED TO THE

DOOR.

7. THE DOOR REVERSES ON OBSTRUCTIONS TO WITHIN 1-1/2" OF THE FLOOR. THE

CONCRETE OR OTHER SURFACE BENEATH THE CLOSED DOOR PROVIDES UNIFORM

CONTACT.

8. THE PLASTIC ENVELOPE FOR THIS MANUAL IS ATTACHED TO THE WALL NEAR THE

PUSH BUTTON OR WALL STATION AND THIS MANUAL IS PLACED THERE FOR OWNER

USE AND REFERENCE.

9. ON DOORS WITH EXTENSION TYPE COUNTERBALANCE SPRINGS, RESTRAINT CABLES

HAVE BEEN INSTALLED THROUGH THE SPRINGS.

10. THERE IS GFI PROTECTION ON THE LINE TO POWER THE OPENER OR IN THE

RECEPTACLE. THIS IS PARTICULARLY IMPORTANT ON INSTALLATIONS INVOLVING

DOORS OF STEEL CONSTRUCTION.

11. ON DOORS WITH ADJUSTABLE BOTTOM EDGES, LOCK EDGES HAVE BEEN LOCKED

AFTER ADJUSTMENT