beautypg.com

Pr 98992 – Alcatel-Lucent 6850 User Manual

Page 85

background image

Open Problem Reports and Feature Exceptions

page 85

OmniSwitch 6800/6850/9000—Release 6.1.3.R01

PR 96011

On an OS9000, NIs will not reset on an unsynchronized takeover if those NIs are manually reset between
configuration change and takeover.

Workaround: There is no known workaround at this time.

PR 98992

The copy working certified flash-synchro command display takes a long time on an OS6800 switch.
OS6800 does not support tffs (true flash file system) but

OS6850

does. So an OS6800 switch takes much

longer whenever there is an operation related to file operation.

Workaround: There is no known workaround at this time.

PR 106872

Upon unsynchronized takeover in Fuji 16 slot chassis, some NIs don't come up gracefully after resetting.

Workaround: Power cycle the NIs that are not UP and ready.