beautypg.com

Alcatel-Lucent 6850 User Manual

Page 81

background image

Open Problem Reports and Feature Exceptions

OmniSwitch 6800/6850/9000—Release 6.1.3.R01

page 81

PR 96327

Extra display character in the swlog. No effect on the switch.

Workaround: There is no known workaround at this time.

PR 96584

On an OS9000, during a reload, when the fabric LED is turned off and on, there is no effect on the switch.

Workaround: There is no known workaround at this time.

PR 98768

If hardware configuration changes are introduced to an OS6800/6850 stack without first ensuring that the
Primary software configuration is certified, it is possible to create an endless synchronization cycle.

Workaround: Before making any hardware configuration changes ensure that the Primary is certified.
Run the copy working certified flash-syncro command before making hardware configuration changes.

PR 98956

An OS6850 supports only single point of failure. Removing multiple stacking cables will introduce multi-
ple points of failure from which the system may not recover.

Workaround: Do not remove multiple stacking cables at the same time.

PR 100244

Installing 6.1.3.R01 images on an OmniSwitch 6800 that is running 5.3.1.R02 code returns an error.

Workaround: The code base has changed significantly from 5.3.1 to 6.1.2. This is especially true of
Jos.img. So the install from 5.3.1 will not be able to support them. Reboot the 6.1.2 images and then do
the install.

PR 100825

On an OS9000, if both CMMs are removed from the chassis, Layer 2 local (local to the NI) traffic with
learned MACs is switched.

Workaround: Insert at least one CMM into the switch to reset the NIs.

PR 103625

Pulling all the cable simultaneously on a stack of 8 OS6850's causes problem.

Workaround: When pulling the cable, the system will start its topology change. Pull the cable one by one
during the topology change will lose the topology information. Try to pull the cable slowly to avoid this
problem.

This manual is related to the following products: