Jumper 501 (jp501), 8installation – LEESON Chassis Mount PWM Control: 175292.00 User Manual
Page 14

8
Installation
A1
A2
+
VD
C
INP
UT
-VD
C
INP
UT
R502
C506
SO501
C504
C505
L501
D501
Q503
Q501
Q504
R
50
1
IL501
Q502
TB501
C501
C502
C507
R
503
JP501
3
2
1
POWER
S3
S2
S1
MIN SPD
IR COMP
CUR LIMIT
ACCEL
MAX SPD
Figure 4. Jumper 501 (JP501)
Jumper 501
Jumper 501 (JP501)
LEESON 17529X.00 series drives are shipped with JP501 open
(no jumper applied). This allows you to use 24 VDC motors with
the 175290.00 and 175291.00, or 48 VDC motors with the
175292.00. To use lower voltage DC motors (12 VDC or 36 VDC,
respectively) jumper pins 2 and 3 with the jumper provided. See
Figure 4 for the location of JP501.
175290.00 = 16 Amp 12/24 VDC
175291.00 = 60 Amp 12/24 VDC
175292.00 = 60 Amp 36/48 VDC