Wiring instructions, Save these instructions, Danger – King Electric ES Electronic User Manual
Page 3
WIRING INSTRUCTIONS
DANGER
!
!
ELECTRIC SHOCK OR FIRE HAZARD
READ ALL WIRE SIZING, VOLTAGE REQUIREMENTS AND SAFETY
DATA TO AVOID PROPERTY DAMAGE AND PERSONAL INJURY
ES-230 & ES-120
Will flash until button
is pushed to stop it.
Defaults to set point
temperature 68°F.
The thermostat will
default to displaying
the room temperature.
The thermostat will
default back to the
room temperature after
a few moments.
To adjust temperature: Tap one of the
arrow keys to change from room
temperature to Set Point temperature. A
thermometer will show up on the display.
This shows that you can now tap the key
up or down to change the temperature of
the room.
4 7/8"
3 1/8"
1 1/4"
2"
DIMENSIONS:
START-UP DISPLAY:
DEFAULT:
ROOM TEMPERATURE:
ROOM TEMPERATURE:
ADJUST MODE:
1 1/4"
BLACK
BLACK
2X4
JUNCTION
BOX
RED
WHITE
BLACK
TO HEATER LOAD
POWER IN
WHITE
2"
BLUE ON ES-230
WHITE ON ES-120
DISPLAY CHANGE
Fahrenheit to Celsius:
On the bottom edge of the thermstat, there are air
vents. In one of the vents on the left side, just
behind the illumination switch, there is a larger
opening with a pin collector attached. With needle
nose pliers, pull the connector off. This will put
the thermostat into the metric Celsius mode.
SAVE THESE INSTRUCTIONS
KING ELECTRICAL MFG. CO. 9131 10TH AVENUE SOUTH SEATTLE, WA 98108 · PH: 206.762.0400 · FAX: 206.763.7738 · www.king-electric.com 3
ESP Instructions 3 10.06.04.ai