Strider essential series, 3 output voltage hold-up time, 4 operation at no load – SilverStone ST50F-ESG User Manual
Page 7: 5 protection 3.5.1 over-voltage protection, 2 over- current protection, Sst-st70f-esg, Sst-st60f-esg, Sst-st50f-esg: over-current test values

STRIDER ESSENTIAL SERIES
06
Output Voltage
Protecting trigger condition
5V
< 45A
12V
< 62A
3.3V
< 60A
3.3 OUTPUT VOLTAGE HOLD-UP TIME
16.0 mS minimum : at 115V / 60 Hz. (80%LOAD)
3.4 OPERATION AT NO LOAD
The power supply shall be capable of being operated with no load on any or all outputs
without damage. For no load on +3.3V & +5V, the output shall not exceed +4.3V & +6.5Vdc
and the power supply may shutdown and require by remote-control or remove AC power restart.
3.5 PROTECTION
3.5.1 OVER-VOLTAGE PROTECTION
In the event of an over-voltage condition on +3.3 & +5Vdc &+12V the power supply shall
shutdown and require remote control or remove the AC mains input to reset the system.
+5V : 6.5V (maximum)
+3.3V : 4.3V (maximum)
+12V : 15.5V (maximum)
3.5.2 OVER- CURRENT PROTECTION
There shall be protection from an output over-current event. The PSU may shutdown
form such an event and require power-on restart. The overload currents should be
ramped at a minimum rate of 10 A/s starting from full load.
SST-ST70F-ESG:
Output Voltage
Protecting trigger condition
5V
< 45A
12V
< 52A
3.3V
< 60A
SST-ST60F-ESG:
Output Voltage
Protecting trigger condition
5V
< 45A
12V
< 46A
3.3V
< 60A
SST-ST50F-ESG:
OVER-CURRENT TEST VALUES: